EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ultra-sensitive nanostructured electrochemical immunosensor for selective monitoring of L-phenylalanine in phenylketonuria patients

Rebecca L Houston, Eric C Y Law, Emad L Izake

Microchimica Acta · 2026

DOI: 10.1007/s00604-026-07836-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2026. Verfasst von Rebecca L Houston und 2 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Physics, Queensland University of Technology, Brisbane, QLD, Australia. rebeccca.houston@hdr.qut.edu.au. Hauptthemen laut MEDLINE: Phenylalanine, Phenylketonurias, Electrochemical Techniques, Biosensing Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Queensland University of Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A low cost and rapid electrochemical immunosensor for direct screening of L-phenylalanine (L-Phe) using square wave voltammetry (SWV) is presented. Fern-like gold nanostructures were electro-deposited onto a screen-printed electrode (SPE) using chronoamperometry (CA), to enhance sensitivity and surface area. A novel light-driven surface functionalisation process was used to decorate the gold nanostructured SPE with target-specific antibody fragments and develop the L-Phe-specific immunosensor. The selectivity of the sensor was confirmed against tyrosine, tryptophan and D-phenylalanine, thus indicating the sensor’s potential for use at points of care (POC) without interference from structurally related biomolecules. The sensor demonstrated high sensitivity across the full clinical range (120 µM-1200 µM) and excellent linearity within the concentration range 1 µM to 2000 µM (R²= 0.99, LOD = 0.3 µM, LOQ = 1 µM). Quantification of L-Phe in human blood dry spots (DBS) by the new sensor and SWV were in excellent agreement with mass spectroscopy (MS) measurements by 2 independent pathology labs. The sensor was successfully integrated with an ultra-compact potentiostat in a Lab-on-a-Phone assembly for L-Phe screening in DBS, thus demonstrating its potential for use at POC and at home by phenylketonuria (PKU) patients in both remote and rural areas.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhenylalaninePhenylketonuriasElectrochemical TechniquesBiosensing TechniquesNanostructuresHumansGoldImmunoassayLimit of DetectionElectrodesMetal Nanoparticles

Stichwörter der Autor:innen

Electrochemical immunosensorFern-like gold nanostructuresLight-driven surface modificationPhenylalaninePhenylketonuria

Substanzen

PhenylalanineGold

Autor:innen und Institutionen

  • School of Chemistry and Physics, Queensland University of Technology, Brisbane, QLD, Australia. rebeccca.houston@hdr.qut.edu.au.
  • The Children's Hospital at Westmead, Sydney, NSW, 2145, Australia.
  • The University of Sydney, Camperdown, NSW, 2050, Australia.
  • School of Chemistry and Physics, Queensland University of Technology, Brisbane, QLD, Australia.
  • Centre for Materials Science, Queensland University of Technology (QUT), 2 George Street, Brisbane, QLD, 4000, Australia.

Förderung

  • Queensland University of Technology

Zitieren

APA

Houston, R. L., Law, E. C. Y., & Izake, E. L. (2026). Ultra-sensitive nanostructured electrochemical immunosensor for selective monitoring of L-phenylalanine in phenylketonuria patients. Microchimica Acta. https://doi.org/10.1007/s00604-026-07836-8

Vancouver

Houston RL, Law ECY, Izake EL. Ultra-sensitive nanostructured electrochemical immunosensor for selective monitoring of L-phenylalanine in phenylketonuria patients. Microchimica Acta. 2026. doi:10.1007/s00604-026-07836-8

BibTeX
@article{Houston2026,
  author = {Houston, Rebecca L and Law, Eric C Y and Izake, Emad L},
  title = {Ultra-sensitive nanostructured electrochemical immunosensor for selective monitoring of L-phenylalanine in phenylketonuria patients},
  journal = {Microchimica Acta},
  year = {2026},
  doi = {10.1007/s00604-026-07836-8}
}
Kostenlos starten →