2D Ti3C2Tx MXene nanozymes based electrochemical MicroRNA biosensor and application to early diagnosis of sepsis-associated acute kidney injury
Microchimica Acta · 2025
DOI: 10.1007/s00604-025-07559-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Xiangyu Deng und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory, University-Town Hospital of Chongqing Medical University, Chongqing, 401331, China. Hauptthemen laut MEDLINE: MicroRNAs, Biosensing Techniques, Electrochemical Techniques, Titanium. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Science and Technology Research Program of Chongqing Municipal Education Commission, Natural Science Foundation of Chongqing.
Themen: Sepsis
Abstract (Originalsprache)
MicroRNA detection-based molecular diagnostic methods offer a favorable pathway for the early diagnosis of sepsis-associated acute kidney injury (SA-AKI), which is crucial for reducing mortality and improving patient outcomes. In this work, a highly sensitive electrochemical biosensor was fabricated for the determination of serum miR-452-5p, an emerging biomarker for SA-AKI, leveraging the novel Ti 3 C 2 T x MXene nanozymes and catalytic hairpin assembly isothermal amplification. Surprisingly, the two-dimensional Ti 3 C 2 T x MXene nanozymes demonstrated remarkable electro-catalytic activity towards choline, wihch was attributed to the strong adsorption interaction between the oxygen atoms on the Ti 3 C 2 T x MXene surface and the hydroxyl group of choline. Based on above-mentioned characteristic of Ti 3 C 2 T x MXene nanozymes, a cascading catalytic amplification strategy by integrating Ti 3 C 2 T x MXene with alkaline phosphatase using phosphorylcholine chloride as the substrate was designed, thereby achieving highly efficient electrochemical signal amplification. The electrochemical biosensing approach exhibited remarkable sensitivity for miR-452-5p detection, with a linear response over a concentration range from 0.1 fM to 10 nM and a low detection limit of 0.09 fM. Additionally, the developed electrochemical biosensor for direct serum miR-452-5p detection present a diagnostic efficiency of 96% in clinical samples analysis, highlighting its strong potential for the early detection and risk assessment of SA-AKI. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Clinical Laboratory, University-Town Hospital of Chongqing Medical University, Chongqing, 401331, China.
- College of Public Health, Chongqing Medical University, Chongqing, 400016, China.
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing, 400016, China.
- Department of Clinical Laboratory, University-Town Hospital of Chongqing Medical University, Chongqing, 401331, China. yurongjun@hospital.cqmu.edu.cn.
- Key Laboratory of Clinical Laboratory Diagnostics (Ministry of Education), College of Laboratory Medicine, Chongqing Medical University, Chongqing, 400016, China. zhaomin@cqmu.edu.cn.
- College of Public Health, Chongqing Medical University, Chongqing, 400016, China. jfqiu@126.com.
Förderung
- National Natural Science Foundation of China
- Science and Technology Research Program of Chongqing Municipal Education Commission
- Natural Science Foundation of Chongqing
- Joint project of Chongqing Health Commission and Science and Technology Bureau
- Chongqing Natural Science Foundation Innovation and Development Joint Fund
Zitieren
APA
Deng, X., Zheng, X., Chen, A., Li, Y., Chen, S., Wu, J., Xue, J., Yu, R., Zhao, M., & Qiu, J. (2025). 2D Ti3C2Tx MXene nanozymes based electrochemical MicroRNA biosensor and application to early diagnosis of sepsis-associated acute kidney injury. Microchimica Acta. https://doi.org/10.1007/s00604-025-07559-2
Vancouver
Deng X, Zheng X, Chen A, Li Y, Chen S, Wu J, et al. 2D Ti3C2Tx MXene nanozymes based electrochemical MicroRNA biosensor and application to early diagnosis of sepsis-associated acute kidney injury. Microchimica Acta. 2025. doi:10.1007/s00604-025-07559-2
BibTeX
@article{Deng2025,
author = {Deng, Xiangyu and Zheng, Xia and Chen, Anyi and Li, Yuqing and Chen, Siling and Wu, Jiangling and Xue, Jianjiang and Yu, Rongjun and Zhao, Min and Qiu, Jingfu},
title = {2D Ti3C2Tx MXene nanozymes based electrochemical MicroRNA biosensor and application to early diagnosis of sepsis-associated acute kidney injury},
journal = {Microchimica Acta},
year = {2025},
doi = {10.1007/s00604-025-07559-2}
}
EUVIMED