A β-cyclodextrin/AuNPs@MWCNT/chitosan-hydrogel-based 3D stochastic sensor for simultaneous determination of vascular cell adhesion molecule-1, interleukin-6, and natriuretic peptide C-type in whole blood samples
Microchimica Acta · 2025
DOI: 10.1007/s00604-025-07514-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Raluca-Ioana Stefan-van Staden und 3 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Street…. Hauptthemen laut MEDLINE: Vascular Cell Adhesion Molecule-1, Interleukin-6, beta-Cyclodextrins, Hydrogels. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 60 Literaturangaben. Gefördert von: Unitatea Executiva pentru Finantarea Invatamantului Superior, a Cercetarii, Dezvoltarii si Inovarii,Romania.
Abstract (Originalsprache)
Molecular recognition and determination of vascular cell adhesion molecule-1 (VCAM-1), interleukin-6 (IL-6), and natriuretic peptide C-type (NPPC) are essential for the early prognosis and diagnosis of cardiovascular diseases, especially in young obese populations. Highly sensitive and selective devices characterized by low Limits of quantification are required for their determination in whole blood. Therefore, a 3D stochastic sensor was developed by immobilizing a chitosan hydrogel onto a carbon paste electrode (used as the support matrix for the hydrogel), which was subsequently modified with gold nanoparticles, multi-walled carbon nanotubes, and β-cyclodextrin (β-CD/AuNPs@MWCNT/CS/CPE). The sensor was designed, characterized, and validated using whole blood samples and compared with commercial enzyme-linked immunoassay (ELISA) kits for the molecular recognition and determination of IL-6, VCAM-1, and NPPC. The sensor exhibited low Limits of quantification: 4.10 × 10-17 g mL-1 for IL-6, 5.00 × 10-16 g mL-1 for VCAM-1, and 1.00 × 10-15 g mL-1 for NPPC, with wide Linear concentration ranges of 4.10 × 10-17-2.00 × 10-7 g mL-1 (IL-6), 5.00 × 10-16-5.00 × 10-8 g mL-1 (VCAM-1), and 1.00 × 10-15-1.00 × 10-9 g mL-1 (NPPC). The recoveries for each biomarker were higher than 99.85%, with relative standard deviations below 1.00%. The sensor can be used as a screening tool for whole blood, enabling rapid molecular recognition and determination of IL-6, VCAM-1, and NPPC.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Street, 060021, Bucharest, Romania. ralucavanstaden@gmail.com.
- Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Street, 060021, Bucharest, Romania.
- National Research and Development Institute for Chemistry and Petrochemistry ICECHIM, 202 Splaiul Independentei Street, 060021, Bucharest, Romania.
Förderung
- Unitatea Executiva pentru Finantarea Invatamantului Superior, a Cercetarii, Dezvoltarii si Inovarii,Romania
Zitieren
APA
Stefan-van Staden, R. I., Stefan, A. I., Georgescu-State, R., & Gifu, I. C. (2025). A β-cyclodextrin/AuNPs@MWCNT/chitosan-hydrogel-based 3D stochastic sensor for simultaneous determination of vascular cell adhesion molecule-1, interleukin-6, and natriuretic peptide C-type in whole blood samples. Microchimica Acta. https://doi.org/10.1007/s00604-025-07514-1
Vancouver
Stefan-van Staden RI, Stefan AI, Georgescu-State R, Gifu IC. A β-cyclodextrin/AuNPs@MWCNT/chitosan-hydrogel-based 3D stochastic sensor for simultaneous determination of vascular cell adhesion molecule-1, interleukin-6, and natriuretic peptide C-type in whole blood samples. Microchimica Acta. 2025. doi:10.1007/s00604-025-07514-1
BibTeX
@article{StefanvanStaden2025,
author = {Stefan-van Staden, Raluca-Ioana and Stefan, Andrada-Ioana and Georgescu-State, Ramona and Gifu, Ioana Catalina},
title = {A β-cyclodextrin/AuNPs@MWCNT/chitosan-hydrogel-based 3D stochastic sensor for simultaneous determination of vascular cell adhesion molecule-1, interleukin-6, and natriuretic peptide C-type in whole blood samples},
journal = {Microchimica Acta},
year = {2025},
doi = {10.1007/s00604-025-07514-1}
}
EUVIMED