EUVIMEDEUVIMED entdecken
Crossref

Carbon nanofiber–enhanced molecular imprinted electrochemical sensor for hypoxanthine detection

Canan Armutcu, Sena Pişkin, Erdoğan Özgür, Mustafa Karakaya, M Emin Çorman, Lokman Uzun

Microchimica Acta · 2025

DOI: 10.1007/s00604-025-07502-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Canan Armutcu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Science, Department of Chemistry, Hacettepe University, Ankara, Turkey. cananarmutcu@hacettepe.edu.tr. Hauptthemen laut MEDLINE: Carbon, Nanofibers, Molecular Imprinting, Electrochemical Techniques. Die Arbeit nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A molecularly imprinted electrochemical sensor (MIP) was developed using thymine-functionalized carbon nanofibers (Thy@CNFs) to enable selective detection of hypoxanthine (HYP). The sensor was fabricated by first depositing Thy@CNFs onto a glassy carbon electrode (GCE), followed by electropolymerization of a pyrrole-co-pyrrole-3-carboxylic acid (Py-co-PyCOOH) copolymer in the presence of HYP. Each modification step was characterized using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), attenuated total reflection-Fourier transform infrared spectroscopy (ATR-FTIR), scanning electron microscopy (SEM), and contact angle measurements. Under optimized conditions, the Thy@CNFs-modified MIP sensor (Thy@CNFs/MIP/GCE) exhibited a linear response to HYP concentrations ranging from 1 × 10-9 to 1 × 10-8 M, with a detection limit of 1.71 × 10-10 M. Finally, the sensor was successfully applied to commercial serum and artificial urine sample, achieving recoveries of 99.55% and 100.17%, respectively, demonstrating its accuracy, precision, and practical applicability in real sample analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CarbonNanofibersMolecular ImprintingElectrochemical TechniquesHypoxanthineMolecularly Imprinted PolymersLimit of DetectionHumansElectrodes

Stichwörter der Autor:innen

CNFsDifferential pulse voltammetryHypoxanthineModified glassy carbon electrodeMolecular imprintingThymine

Substanzen

CarbonHypoxanthineMolecularly Imprinted Polymers

Autor:innen und Institutionen

  • Faculty of Science, Department of Chemistry, Hacettepe University, Ankara, Turkey. cananarmutcu@hacettepe.edu.tr.
  • Faculty of Science, Department of Chemistry, Hacettepe University, Ankara, Turkey.
  • Faculty of Engineering & Architecture, Department of Energy Systems, Sinop University, Sinop, Turkey.
  • Gülhane Faculty of Pharmacy, Department of Biochemistry, University of Health Sciences, Ankara, Turkey.

Zitieren

APA

Armutcu, C., Pişkin, S., Özgür, E., Karakaya, M., Çorman, M. E., & Uzun, L. (2025). Carbon nanofiber–enhanced molecular imprinted electrochemical sensor for hypoxanthine detection. Microchimica Acta. https://doi.org/10.1007/s00604-025-07502-5

Vancouver

Armutcu C, Pişkin S, Özgür E, Karakaya M, Çorman ME, Uzun L. Carbon nanofiber–enhanced molecular imprinted electrochemical sensor for hypoxanthine detection. Microchimica Acta. 2025. doi:10.1007/s00604-025-07502-5

BibTeX
@article{Armutcu2025,
  author = {Armutcu, Canan and Pişkin, Sena and Özgür, Erdoğan and Karakaya, Mustafa and Çorman, M Emin and Uzun, Lokman},
  title = {Carbon nanofiber–enhanced molecular imprinted electrochemical sensor for hypoxanthine detection},
  journal = {Microchimica Acta},
  year = {2025},
  doi = {10.1007/s00604-025-07502-5}
}
Kostenlos starten →