Lysozyme detection in body biofluids by dual-decorated graphene oxide-gold nanoparticles-based biomimetic plasmonic sensor

Seçkin Kılıç, Fatma Yılmaz, Semra Akgönüllü, Ilgım Göktürk, Adil Denizli

Microchimica Acta · 2025

DOI: 10.1007/s00604-025-07470-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Seçkin Kılıç und 4 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Science and Engineering, Department of Chemistry, Hacettepe University, 06800, Ankara, Turkey. Hauptthemen laut MEDLINE: Graphite, Muramidase, Gold, Metal Nanoparticles. Die Arbeit nennt 50 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate measurement of lysozyme in human biofluids is essential for early disease diagnosis and treatment monitoring. This work presents a plasmonic sensing platform utilizing AuNPs-GO/MIP, which integrates gold nanoparticles (AuNPs) and graphene oxide (GO) through molecular imprinting for the detection of lysozyme in urine, serum, and saliva. The enhancement in sensor sensitivity resulting from the addition of AuNPs and GO was verified by comparing it with a sensor lacking these components. We fabricated a AuNPs-GO/MIP surface plasmon resonance (SPR) chip using N-methacryloyl-L-cysteine and N-methacryloyl-L-tryptophan as functional monomers; the platform enables sensitive, low-cost, label-free lysozyme detection in buffer and synthetic biofluids, with no additional coupling chemistry. The imprinting efficiency was evaluated with a non-imprinted AuNPs-GO/NIP SPR sensor, yielding a remarkable imprinting factor (IF: 4.98). The sensor showed a linear detection response (R2 = 0.9794) for lysozyme in buffer (pH 7.4 PBS) within 0.01-0.5 nM, with a detection limit of 0.0015 nM. The sensor exhibited 4.27 times higher selectivity for lysozyme compared with myoglobin and 2.36 times compared with cytochrome c. The sensor exhibited high repeatability (RSD < 1.5%, n = 6), with no measurable decline in signal after six cycles. The low RSD for the AuNPs-GO/MIP SPR sensor implies it is reusable with high accuracy. Finally, detection experiments were conducted using the sensor on artificial urine, serum, and saliva samples to assess the matrix effect.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GraphiteMuramidaseGoldMetal NanoparticlesSurface Plasmon ResonanceBiomimetic MaterialsHumansLimit of DetectionSalivaMolecular Imprinting

Stichwörter der Autor:innen

Biomimetic sensingLysozyme detectionMolecularly imprinted polymerSurface plasmon resonance

Substanzen

GraphiteMuramidaseGoldgraphene oxide

Autor:innen und Institutionen

  • Graduate School of Science and Engineering, Department of Chemistry, Hacettepe University, 06800, Ankara, Turkey.
  • Biochemistry Division, Department of Chemistry, Hacettepe University, Ankara, Turkey.
  • Department of Chemistry Technologies, Bolu Abant Izzet Baysal University, 14030, Bolu, Turkey.
  • Graduate School of Science and Engineering, Department of Chemistry, Hacettepe University, 06800, Ankara, Turkey. denizli@hacettepe.edu.tr.

Zitieren

APA

Kılıç, S., Yılmaz, F., Akgönüllü, S., Göktürk, I., & Denizli, A. (2025). Lysozyme detection in body biofluids by dual-decorated graphene oxide-gold nanoparticles-based biomimetic plasmonic sensor. Microchimica Acta. https://doi.org/10.1007/s00604-025-07470-w

Vancouver

Kılıç S, Yılmaz F, Akgönüllü S, Göktürk I, Denizli A. Lysozyme detection in body biofluids by dual-decorated graphene oxide-gold nanoparticles-based biomimetic plasmonic sensor. Microchimica Acta. 2025. doi:10.1007/s00604-025-07470-w

BibTeX
@article{Kl2025,
  author = {Kılıç, Seçkin and Yılmaz, Fatma and Akgönüllü, Semra and Göktürk, Ilgım and Denizli, Adil},
  title = {Lysozyme detection in body biofluids by dual-decorated graphene oxide-gold nanoparticles-based biomimetic plasmonic sensor},
  journal = {Microchimica Acta},
  year = {2025},
  doi = {10.1007/s00604-025-07470-w}
}
Kostenlos starten →