Paper-based and chemical-free dual low-cost electrochemical biosensor for rapid detection of Escherichia coli O157:H7

Manman Du, Junting Zhou, Tianteng Hao, Xinwu Xie, Zhi Cheng, Can Wang

Microchimica Acta · 2025

DOI: 10.1007/s00604-025-07451-z ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Manman Du und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Environmental Science and Engineering, Tianjin University, Tianjin, 300072, China. Hauptthemen laut MEDLINE: Escherichia coli O157, Biosensing Techniques, Paper, Electrochemical Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 78 Literaturangaben. Gefördert von: Key Research and Development Plan of Tianjin.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A low-cost electrical assay is reported using a paper-based electrochemical biosensor modified with carboxylated graphene oxide (GO-COOH), which is capable of directly immobilizing antibodies without chemical cross-linkers and is promising for the rapid detection of Escherichia coli (E. coli) O157:H7 in low-income areas. Antibodies were immobilized on the surface of the GO-COOH/C electrode at appropriate concentrations to directly and specifically capture targets. The GO-COOH/C paper-based electrochemical biosensor was capable of detecting as low as 0.26 CFU/mL of E. coli O157:H7 within 16 s selectively. The practicality of the GO-COOH/C paper-based electrochemical biosensor was evaluated using tap and river water samples. The detection results were similar to those of the standard plate culture method, but the analysis speed is much faster and has good cost-effectiveness (about US$ 1.81). The GO-COOH/C paper-based electrochemical biosensor stands out among various analytical techniques due to its dual low-cost advantages and excellent detection capabilities for E. coli O157:H7, which provide a strong guarantee for water quality safety in low-income areas.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Escherichia coli O157Biosensing TechniquesPaperElectrochemical TechniquesGraphiteAntibodies, ImmobilizedElectrodesLimit of Detection

Stichwörter der Autor:innen

Escherichia coli O157:H7Carboxylated graphene oxideDifferential pulse voltammetryPaper-based electrochemical biosensorWater safety

Substanzen

Graphitegraphene oxideAntibodies, Immobilized

Autor:innen und Institutionen

  • School of Environmental Science and Engineering, Tianjin University, Tianjin, 300072, China.
  • Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 300161, China.
  • Tianjin Key Lab of Indoor Air Environmental Quality Control, Tianjin, 300072, China.
  • School of Electronic Information and Automation, Tianjin University of Science and Technology, Tianjin, 300222, China.
  • Systems Engineering Institute, Academy of Military Sciences, People's Liberation Army, Tianjin, 300161, China. xinwuxie@163.com.
  • National Bio-Protection Engineering Center, Tianjin, 300161, China. xinwuxie@163.com.

Förderung

  • Key Research and Development Plan of Tianjin

Zitieren

APA

Du, M., Zhou, J., Hao, T., Xie, X., Cheng, Z., & Wang, C. (2025). Paper-based and chemical-free dual low-cost electrochemical biosensor for rapid detection of Escherichia coli O157:H7. Microchimica Acta. https://doi.org/10.1007/s00604-025-07451-z

Vancouver

Du M, Zhou J, Hao T, Xie X, Cheng Z, Wang C. Paper-based and chemical-free dual low-cost electrochemical biosensor for rapid detection of Escherichia coli O157:H7. Microchimica Acta. 2025. doi:10.1007/s00604-025-07451-z

BibTeX
@article{Du2025,
  author = {Du, Manman and Zhou, Junting and Hao, Tianteng and Xie, Xinwu and Cheng, Zhi and Wang, Can},
  title = {Paper-based and chemical-free dual low-cost electrochemical biosensor for rapid detection of Escherichia coli O157:H7},
  journal = {Microchimica Acta},
  year = {2025},
  doi = {10.1007/s00604-025-07451-z}
}
Kostenlos starten →