EUVIMEDEUVIMED entdecken
Crossref

Photoelectrochemical biosensor based on Bi2S3/Bi2O2CO3 for lactic acid detection

Zhongzhou Si, Rong Shao, Ting Li, Minghui Yang

Microchimica Acta · 2025

DOI: 10.1007/s00604-025-07434-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Zhongzhou Si und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Liver Transplantation, The Second Xiang-Ya Hospital, Central South University, Changsha, 410011, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Lactic Acid, Bismuth, Electrochemical Techniques. Die Arbeit nennt 24 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Hunan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Photoelectrochemical biosensor based on Bi2S3/Bi2O2CO3 heterojunction as photoelectrically active material and lactate oxidase was constructed for sensitive detection of lactic acid in serum. Topological transformation method was utilized to prepare Bi2S3/Bi2O2CO3 composites, which can generate electron-hole pairs triggering photoelectrochemical reactions under light illumination. The Bi2S3/Bi2O2CO3 heterojunction effectively promoted the separation and transportation of photogenerated electrons and holes, leading to improved photoelectric conversion efficiency. Lactic acid is catalyzed by lactate oxidase to generate H2O2, which reacts with photogenerated holes, leading to photocurrent increase, achieving quantitative detection of lactic acid. The prepared biosensor has a wide detection range for lactic acid from 0.01 mM to 10 mM, with detection limit as low as 0.006 mM. In addition, the detection of lactic acid in serum samples further validated the potential application of the sensor.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesLactic AcidBismuthElectrochemical TechniquesSulfidesLimit of DetectionMixed Function OxygenasesHumansPhotochemical ProcessesHydrogen Peroxide

Stichwörter der Autor:innen

Bismuth-based materialsLactateLactate oxidaseModified glassy carbon electrodePhotoelectrochemical sensors

Substanzen

Lactic AcidBismuthlactate 2-monooxygenaseMixed Function OxygenasesHydrogen PeroxideSulfides

Autor:innen und Institutionen

  • Department of Liver Transplantation, The Second Xiang-Ya Hospital, Central South University, Changsha, 410011, China.
  • Transplant Medical Research Center, The Second Xiang-Ya Hospital, Central South University, Changsha, 410011, China.
  • Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China.
  • Department of Liver Transplantation, The Second Xiang-Ya Hospital, Central South University, Changsha, 410011, China. liting001@csu.edu.cn.
  • Transplant Medical Research Center, The Second Xiang-Ya Hospital, Central South University, Changsha, 410011, China. liting001@csu.edu.cn.
  • Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha, 410083, China. yangminghui@csu.edu.cn.

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Hunan Province

Zitieren

APA

Si, Z., Shao, R., Li, T., & Yang, M. (2025). Photoelectrochemical biosensor based on Bi2S3/Bi2O2CO3 for lactic acid detection. Microchimica Acta. https://doi.org/10.1007/s00604-025-07434-0

Vancouver

Si Z, Shao R, Li T, Yang M. Photoelectrochemical biosensor based on Bi2S3/Bi2O2CO3 for lactic acid detection. Microchimica Acta. 2025. doi:10.1007/s00604-025-07434-0

BibTeX
@article{Si2025,
  author = {Si, Zhongzhou and Shao, Rong and Li, Ting and Yang, Minghui},
  title = {Photoelectrochemical biosensor based on Bi2S3/Bi2O2CO3 for lactic acid detection},
  journal = {Microchimica Acta},
  year = {2025},
  doi = {10.1007/s00604-025-07434-0}
}
Kostenlos starten →