Two approaches for mercury determination in environmental and food monitoring via catalytic fluorometry of Au-Hg amalgamation using a laser-printed paper sensor and microcentrifuge tube test kit
Microchimica Acta · 2025
DOI: 10.1007/s00604-025-07412-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Nutthaporn Malahom und 9 weiteren Autor:innen. Beteiligte Einrichtung: Futuristic Science Research Center, School of Science, Walailak University, 222 Thaiburi, Thasala District, Nakhon Si Thammarat, 80160, Thailand. Hauptthemen laut MEDLINE: Mercury, Gold, Fluorometry, Food Contamination. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: The National Research Council of Thailand.
Abstract (Originalsprache)
Two selective methods were developed for detecting mercury ions (Hg2⁺) in food and water samples using catalytic fluorometry based on Au-Hg amalgamation with enhanced peroxidase-like activity. These approaches include (i) a laser-printed microfluidic paper-based analytical device (LP-µPAD) and (ii) a paper-based microcentrifuge tube test kit. The LP-µPAD was fabricated via commercial laser printing and integrated gold nanoparticles (AuNPs) with o-phenylenediamine (OPD) and hydrogen peroxide (H₂O₂). The test kit enabled Hg2⁺ detection in food by reducing Hg2⁺ to Hg⁰ with stannous chloride, facilitating Au-Hg amalgam formation in the detection zone. Both approaches utilized the Au-Hg amalgam to catalyze H₂O₂-mediated oxidation of OPD, generating fluorescent 2,3-diaminophenazine (DAP), further enhancing fluorescence intensity in proportion to Hg2⁺ concentrations. The LP-µPAD exhibited a detection range of 3.0-20.0 µg L⁻1 with a limit of detection (LOD) of 1.65 µg L⁻1, whereas the test kit provided a detection range of 0.1-1.0 mg L⁻1 with an LOD of 0.08 mg L⁻1. Both sensors showed high selectivity for Hg2⁺ over other ions and performed well in real sample analyses, aligning closely with results from conventional methods.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Futuristic Science Research Center, School of Science, Walailak University, 222 Thaiburi, Thasala District, Nakhon Si Thammarat, 80160, Thailand.
- Research Center for Theoretical Simulation and Applied Research in Bioscience and Sensing, Walailak University, Thasala, Nakhon Si Thammarat, 80160, Thailand.
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand.
- Nanomaterials Science, Sensors & Catalysis for Problem-Based Projects, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand.
- Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Patumwan, Bangkok, 10330, Thailand.
- Green Chemistry for Fine Chemical Production and Environmental Remediation Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Patumwan, Bangkok, 10330, Thailand.
Förderung
- The National Research Council of Thailand
Zitieren
APA
Malahom, N., Boonthod, S., Veerasup, N., Pajarean, C., Prakobkij, A., Anutrasakda, W., Citterio, D., Amatatongchai, M., Nacapricha, D., & Jarujamrus, P. (2025). Two approaches for mercury determination in environmental and food monitoring via catalytic fluorometry of Au-Hg amalgamation using a laser-printed paper sensor and microcentrifuge tube test kit. Microchimica Acta. https://doi.org/10.1007/s00604-025-07412-6
Vancouver
Malahom N, Boonthod S, Veerasup N, Pajarean C, Prakobkij A, Anutrasakda W, et al. Two approaches for mercury determination in environmental and food monitoring via catalytic fluorometry of Au-Hg amalgamation using a laser-printed paper sensor and microcentrifuge tube test kit. Microchimica Acta. 2025. doi:10.1007/s00604-025-07412-6
BibTeX
@article{Malahom2025,
author = {Malahom, Nutthaporn and Boonthod, Sukanya and Veerasup, Nattapong and Pajarean, Chaiwat and Prakobkij, Akarapong and Anutrasakda, Wipark and Citterio, Daniel and Amatatongchai, Maliwan and Nacapricha, Duangjai and Jarujamrus, Purim},
title = {Two approaches for mercury determination in environmental and food monitoring via catalytic fluorometry of Au-Hg amalgamation using a laser-printed paper sensor and microcentrifuge tube test kit},
journal = {Microchimica Acta},
year = {2025},
doi = {10.1007/s00604-025-07412-6}
}
EUVIMED