Design of halochromic cellulosic materials and smart textiles for continuous wearable optical monitoring of epidermal pH
Microchimica Acta · 2025-07 · 192 (7)
DOI: 10.1007/s00604-025-07259-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 04.06.2025. Verfasst von Gerhard J Mohr und 5 weiteren Autor:innen. Beteiligte Einrichtung: Joanneum Research Forschungsgesellschaft mbH - Materials, Franz-Pichler-Straße 30, Weiz, A-8160, Austria. Gerhard.Mohr@joanneum.at. Hauptthemen laut MEDLINE: Cellulose, Wearable Electronic Devices, Textiles, Epidermis. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Austrian Research Promotion Agency (FFG), Croatian Science Foundation, JOANNEUM RESEARCH Forschungsgesellschaft mbH.
Abstract (Originalsprache)
The direct on-body monitoring of sweat pH and skin pH can provide vanguard information about a person’s health status and overall fitness or wellbeing. Sweat pH in particular is a readily accessible biomarker that may be determined with low-cost, non-invasive epidermal patches. With this in mind, we have created a diverse set of wearable halochromic materials, suitable for real-time and reversible monitoring of epidermal pH. A range of cellulosic materials in the form of nanocrystals, microcellulose particles, transparent cellulose films and paper were covalently functionalised with a 2-hydroxyethylsulfonyl azo pH indicator dye by vinylsulfonyl conjugation. Comparative analysis of the photo-physical and analytical properties was performed, and the apparent acid–base equilibrium constants — p K app values of the immobilised indicator — ranging from 5.6 for cellulose paper to 6.9 for nanocellulose particles, cover the physiological range of epidermal sweat and skin pH. A polyester textile — typical of modern sports apparel — was subsequently functionalised with the biocompatible hydrogel containing the halochromic cellulose microparticles. The colour change of the smart textile was found to be fully reversible ( RSD = 0.14%) and its pH response highly stable for over 280 min upon continuous exposure to pH buffers (signal change of 0.16%). The halochromic textile was characterised with custom-made low-power wearable optoelectronics combining a reflectometer and real-time data logger, and the system bench-marked against a calibrated laboratory glass pH electrode and meter. The wearable optoelectronic and halochromic textile system was able to continuously monitor pH in buffer solutions over the physiologically relevant range with an accuracy of 0.18 pH and precision of 0.05 pH units. Graphical abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Joanneum Research Forschungsgesellschaft mbH - Materials, Franz-Pichler-Straße 30, Weiz, A-8160, Austria. Gerhard.Mohr@joanneum.at.
- Faculty of Chemical Engineering and Technology, University of Zagreb, Marulićev Trg 19, Zagreb, 10000, Croatia.
- Joanneum Research Forschungsgesellschaft mbH - Materials, Franz-Pichler-Straße 30, Weiz, A-8160, Austria.
- GoSense Wireless Ltd, Cambridge, CB23 6 FN, UK.
- Faculty of Chemical Engineering and Technology, University of Zagreb, Marulićev Trg 19, Zagreb, 10000, Croatia. imurkov@fkit.unizg.hr.
Förderung
- Austrian Research Promotion Agency (FFG)
- Croatian Science Foundation
- JOANNEUM RESEARCH Forschungsgesellschaft mbH
Zitieren
APA
Mohr, G. J., Kassal, P., Žuvić, I., Krawczyk, K. K., Steinberg, M. D., & Steinberg, I. M. (2025). Design of halochromic cellulosic materials and smart textiles for continuous wearable optical monitoring of epidermal pH. Microchimica Acta, 192(7). https://doi.org/10.1007/s00604-025-07259-x
Vancouver
Mohr GJ, Kassal P, Žuvić I, Krawczyk KK, Steinberg MD, Steinberg IM. Design of halochromic cellulosic materials and smart textiles for continuous wearable optical monitoring of epidermal pH. Microchimica Acta. 2025;192(7). doi:10.1007/s00604-025-07259-x
BibTeX
@article{Mohr2025,
author = {Mohr, Gerhard J and Kassal, Petar and Žuvić, Iva and Krawczyk, Krzysztof K and Steinberg, Matthew D and Steinberg, Ivana Murković},
title = {Design of halochromic cellulosic materials and smart textiles for continuous wearable optical monitoring of epidermal pH},
journal = {Microchimica Acta},
year = {2025},
volume = {192},
number = {7},
doi = {10.1007/s00604-025-07259-x}
}
EUVIMED