Ultrasmall high-entropy alloy-nanolabels based immunochromatographic test strip for rapid, ultrasensitive, and catalytic detection of Staphylococcus aureus
Microchimica Acta · 2025
DOI: 10.1007/s00604-025-07213-x ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Wei Huang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Medical College, Guizhou University, Guiyang, 550025, Guizhou, China. Hauptthemen laut MEDLINE: Staphylococcus aureus, Alloys, Chromatography, Affinity. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: Guizhou Provincial Science and Technology Department, Guizhou Provincial Science and Technology Department,China, National Natural Science Foundation of China.
Abstract (Originalsprache)
The use of ultrasmall high-entropy alloys (HEAs, ≈5 nm) with unique catalytic properties, integrating them into lateral flow immunoassay (LFIA) for the detection of Staphylococcus aureus is proposed. Under optimal conditions, the detection limits of the HEAs-based LFIA were 1.5 × 103 CFU/mL via direct coloration and 15 CFU/mL using the DAB-enhanced catalytic signal, representing improvements of 103-fold and 105-fold, respectively. The HEAs demonstrated superior performance compared with traditional AuNPs, including enhanced sensitivity and high peroxidase activity (Km = 0.066 M, Vmax = 1.132 × 10-6 M min-1), as well as excellent specificity and repeatability, with relative standard deviation (RSD) of less than 10%. Moreover, the incubation time for HEAs functionalized with antibodies to bind Staphylococcus aureus was only 5 min, compared with 20 min for functionalized AuNPs. The method also showed high specificity, effectively discriminating Staphylococcus aureus from other foodborne pathogens. The HEAs-based LFIA was successfully applied to food sample analysis, including milk and orange juice, demonstrating its robust applicability for real-world detection scenarios. This approach not only lowered the detection limit but also reduced the total detection time, making it a highly promising candidate for on-site detection of Staphylococcus aureus and other foodborne pathogens by simply changing the recognition element.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Medical College, Guizhou University, Guiyang, 550025, Guizhou, China.
- NHC Key Laboratory of Pulmonary Immunological Diseases, Guizhou Provincial People's Hospital, Guiyang, 550002, Guizhou, China.
- Department of Laboratory Medicine, Guizhou Provincial People's Hospital, Guiyang, 550002, Guizhou, China.
- Renal Division, Department of Medicine, Guizhou Provincial People's Hospital, Guiyang, 550002, Guizhou, China.
- Medical College, Guizhou University, Guiyang, 550025, Guizhou, China. yanzhagz@126.com.
- Department of Laboratory Medicine, Guizhou Provincial People's Hospital, Guiyang, 550002, Guizhou, China. yanzhagz@126.com.
Förderung
- Guizhou Provincial Science and Technology Department
- Guizhou Provincial Science and Technology Department,China
- National Natural Science Foundation of China
Zitieren
APA
Huang, W., Ren, Z., Li, X., Chen, R., Fan, D., Da, J., Zha, Y., & Xu, Y. (2025). Ultrasmall high-entropy alloy-nanolabels based immunochromatographic test strip for rapid, ultrasensitive, and catalytic detection of Staphylococcus aureus. Microchimica Acta. https://doi.org/10.1007/s00604-025-07213-x
Vancouver
Huang W, Ren Z, Li X, Chen R, Fan D, Da J, et al. Ultrasmall high-entropy alloy-nanolabels based immunochromatographic test strip for rapid, ultrasensitive, and catalytic detection of Staphylococcus aureus. Microchimica Acta. 2025. doi:10.1007/s00604-025-07213-x
BibTeX
@article{Huang2025,
author = {Huang, Wei and Ren, Zhen and Li, Xukui and Chen, Rong and Fan, Dinglin and Da, Jingjing and Zha, Yan and Xu, Yongjie},
title = {Ultrasmall high-entropy alloy-nanolabels based immunochromatographic test strip for rapid, ultrasensitive, and catalytic detection of Staphylococcus aureus},
journal = {Microchimica Acta},
year = {2025},
doi = {10.1007/s00604-025-07213-x}
}