EUVIMEDEUVIMED entdecken
Crossref

A ratiometric electrochemiluminescent strategy for sensitive detection of dopamine based on g-C3N4/luminol-functioned carbon spheres

Hui Zhang, Yahui Ji, Nana You, Xiaoping Hu, Feifei Chen, Fei Wang, Gen Liu

Microchimica Acta · 2025

DOI: 10.1007/s00604-025-07211-z ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Hui Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Green and Precise Synthetic Chemistry and Applications, Ministry of Education Anhui Provincial Key Laboratory of Synthetic Chemistr…. Hauptthemen laut MEDLINE: Dopamine, Luminol, Electrochemical Techniques, Luminescent Measurements. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ratiometric electrochemiluminescence (ECL) assays have attracted widespread attention in biosensing owing to their precise measurements by eliminating environmental interferences. In this work, g-C3N4, gold nanoparticles, CuO and luminol were integrated onto hollow carbon spheres (HCS) in sequence to fabricate potential-resolved ECL nanoprobes. The system consists of g-C3N4 as cathode ECL emitters and luminol as anode ECL emitters. The ECL of g-C3N4 is quenched by CuO due to the resonance energy transfer (RET). However, after adding dopamine (DA), the ECL signal is restored due to the redox reaction between CuO and DA. Meanwhile, there is a quenching effect between DA and luminol because DA interferes with the radical reaction process of luminol. Therefore, DA causes the reciprocal changes in cathodic ECL and anodic ECL. This phenomenon can be leveraged to create a ratiometric ECL signal, enabling the quantitative detection of DA. The developed ECL sensor exhibited a sensitive detection toward DA, performing a wide linearity in the range 5.0 × 10-4 ~ 1.0 × 10-9 M with a low detection limit of 2.3 × 10-11 M (S/N = 3). Furthermore, this strategy exhibited a good practicality to detect DA in human urine, providing a promising strategy in ECL bioanalysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DopamineLuminolElectrochemical TechniquesLuminescent MeasurementsCarbonNitrilesLimit of DetectionGoldMetal NanoparticlesHumansCopperBiosensing Techniques

Stichwörter der Autor:innen

DopamineElectrochemiluminescenceG-C3N4LuminolModified glassy carbon electrodeRatiometric sensor

Substanzen

DopamineLuminolCarbonGoldNitrilesCoppercyanogen

Autor:innen und Institutionen

  • Key Laboratory of Green and Precise Synthetic Chemistry and Applications, Ministry of Education Anhui Provincial Key Laboratory of Synthetic Chemistry and Applications, College of Chemistry and Materials Science, Huaibe…

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Zhang, H., Ji, Y., You, N., Hu, X., Chen, F., Wang, F., & Liu, G. (2025). A ratiometric electrochemiluminescent strategy for sensitive detection of dopamine based on g-C3N4/luminol-functioned carbon spheres. Microchimica Acta. https://doi.org/10.1007/s00604-025-07211-z

Vancouver

Zhang H, Ji Y, You N, Hu X, Chen F, Wang F, et al. A ratiometric electrochemiluminescent strategy for sensitive detection of dopamine based on g-C3N4/luminol-functioned carbon spheres. Microchimica Acta. 2025. doi:10.1007/s00604-025-07211-z

BibTeX
@article{Zhang2025,
  author = {Zhang, Hui and Ji, Yahui and You, Nana and Hu, Xiaoping and Chen, Feifei and Wang, Fei and Liu, Gen},
  title = {A ratiometric electrochemiluminescent strategy for sensitive detection of dopamine based on g-C3N4/luminol-functioned carbon spheres},
  journal = {Microchimica Acta},
  year = {2025},
  doi = {10.1007/s00604-025-07211-z}
}
Kostenlos starten →