EUVIMEDEUVIMED entdecken
Crossref

Electrochemical immunosensor based on poly(5-aminoindole) for cancer biomarker pentraxin-3 detection

Katesara Phasuksom, Natthaporn Thongwattana, Nuttha Ariyasajjamongkol, Napa Parinyanitikul, Anuvat Sirivat

Microchimica Acta · 2025

DOI: 10.1007/s00604-025-07174-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Katesara Phasuksom und 4 weiteren Autor:innen. Beteiligte Einrichtung: Conductive and Electroactive Polymers Research Unit, The Petroleum and Petrochemical College, Chulalongkorn University, Bangkok, Thailand. Hauptthemen laut MEDLINE: C-Reactive Protein, Serum Amyloid P-Component, Biomarkers, Tumor, Electrochemical Techniques. Die Arbeit nennt 58 Literaturangaben. Gefördert von: the Ratchadapisek Somphot Fund for Postdoctoral Fellowship of Chulalongkorn University, the National Research Council of Thailand, the Thailand Science Research and Innovation Fund (TSRI-CU) of Chulalongkorn University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pentraxin-3 (PTX-3) plays a critical role in regulating inflammation, immune response, angiogenesis, and tissue remodeling. As a serum biomarker, it holds a potential in cancer diagnostics and monitoring. Elevated expression of PTX-3 has been found in various cancers, namely lung, prostate, gastric, breast, and hepatic cancers. Here, a PTX-3 immunosensor was fabricated by utilizing poly(5-aminoindole) (P5AIn) to increase the current response and the electroactive surface area (ESA). (3-Aminopropyl)triethoxysilane (APTES) was used as a linker and as an electron transfer enhancer. The developed PTX-3 immunosensor (BSA/anti-PTX-3/APTES/P5AIn/SPCE) shows excellent performance for PTX-3 detection in a wide concentration range from 0.0001 to 2000 ng/mL with the LOD of 0.012 pg/mL. Furthermore, the sensor possessed good reproducibility (%RSD = 0.78), a long shelf-life of at least 4 weeks (% RSD = 0.89), and high specificity to PTX-3. The fabricated PTX-3 immunosensor was demonstrated in the measurement of PTX-3 concentrations in real blood serums from gastric patients. It has been shown as a potentially promising portable sensor for cancer diagnostics and monitoring for cancer patients in remote areas with a low cost.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

C-Reactive ProteinSerum Amyloid P-ComponentBiomarkers, TumorElectrochemical TechniquesBiosensing TechniquesIndolesHumansImmunoassayLimit of DetectionAntibodies, ImmobilizedReproducibility of ResultsSilanesPentraxins

Stichwörter der Autor:innen

Cancer biomarkersConductive polymersElectroanalysisElectrochemical immunosensorsPentraxin- 3Poly(5-aminoindole)

Substanzen

C-Reactive ProteinSerum Amyloid P-ComponentBiomarkers, TumorAntibodies, ImmobilizedIndolesSilanesPentraxins

Autor:innen und Institutionen

  • Conductive and Electroactive Polymers Research Unit, The Petroleum and Petrochemical College, Chulalongkorn University, Bangkok, Thailand.
  • Division of Medical Oncology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
  • Department of Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
  • Conductive and Electroactive Polymers Research Unit, The Petroleum and Petrochemical College, Chulalongkorn University, Bangkok, Thailand. anuvat.s@chula.ac.th.

Förderung

  • the Ratchadapisek Somphot Fund for Postdoctoral Fellowship of Chulalongkorn University
  • the National Research Council of Thailand
  • the Thailand Science Research and Innovation Fund (TSRI-CU) of Chulalongkorn University

Zitieren

APA

Phasuksom, K., Thongwattana, N., Ariyasajjamongkol, N., Parinyanitikul, N., & Sirivat, A. (2025). Electrochemical immunosensor based on poly(5-aminoindole) for cancer biomarker pentraxin-3 detection. Microchimica Acta. https://doi.org/10.1007/s00604-025-07174-1

Vancouver

Phasuksom K, Thongwattana N, Ariyasajjamongkol N, Parinyanitikul N, Sirivat A. Electrochemical immunosensor based on poly(5-aminoindole) for cancer biomarker pentraxin-3 detection. Microchimica Acta. 2025. doi:10.1007/s00604-025-07174-1

BibTeX
@article{Phasuksom2025,
  author = {Phasuksom, Katesara and Thongwattana, Natthaporn and Ariyasajjamongkol, Nuttha and Parinyanitikul, Napa and Sirivat, Anuvat},
  title = {Electrochemical immunosensor based on poly(5-aminoindole) for cancer biomarker pentraxin-3 detection},
  journal = {Microchimica Acta},
  year = {2025},
  doi = {10.1007/s00604-025-07174-1}
}
Kostenlos starten →