EUVIMEDEUVIMED entdecken
Crossref

Development of a syringe-hosted load-and-read immunoassay device using autoinjected distance readout in paper inserts

Haojie Li, Jie Liu, Cuili Li, Runze Wang, Sapna Kannan, XiuJun Li, Guanglei Fu

Microchimica Acta · 2025

DOI: 10.1007/s00604-025-07052-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2025. Verfasst von Haojie Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Pharmacy, Key Laboratory of Molecular Pharmacology and Drug Evaluation, Ministry of Education, Collaborative Innovation Center of Advanced …. Hauptthemen laut MEDLINE: Prostate-Specific Antigen, Syringes, Paper. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Natural Science Foundation of Shandong Province, Research Starting Foundation of Yantai University, Cancer Prevention and Research Institute of Texas.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pressure-based signal readout is promising for developing instrument-free immunoassays, but new detection methods are desirable to further advance the applicability of point-of-care testing (POCT). Herein, we developed a syringe-hosted load-and-read immunoassay device using autoinjected distance readout in paper inserts. The device was composed of multiple disposable syringes as the host for immuno-recognition, a three-dimensional (3D)-printed loading magazine of the syringes, and paper inserts to the magazine for distance signal readout. Using prostate-specific antigen (PSA) as a model target, the immuno-recognition system was constructed on the inner cylinder walls of the syringes. The immuno-captured platinum nanoparticles (Pt NPs) catalyzed the decomposition of H2O2 to produce O2 in the cylinders, driving the automatic quantitative injection behavior of the syringes. By loading the syringes into the magazine, the autoinjected liquids were received by the paper inserts to display the immunoassay signals as a visual traveling distance of liquids. PSA was determined with a low limit of detection (LOD) of 0.32 ng/mL and high accuracy in testing clinical serum specimens. Given the advantages of the simple syringe-hosted immuno-recognition method and the load-and-read signal readout in the paper inserts, the immunoassay device shows great potential in POCT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prostate-Specific AntigenSyringesPaperImmunoassayPlatinumMetal NanoparticlesHumansLimit of DetectionHydrogen PeroxideEquipment Design

Stichwörter der Autor:innen

ImmunoassaysPaper devicesPoint-of-care testingPressure-based detection

Substanzen

Prostate-Specific AntigenPlatinumHydrogen Peroxide

Autor:innen und Institutionen

  • School of Pharmacy, Key Laboratory of Molecular Pharmacology and Drug Evaluation, Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong ,Ya…
  • Department of Clinical Laboratory, Affiliated Yantai Yuhuangding Hospital of Qingdao University, Yantai, Shandong, 264000, China.
  • School of Electromechanical and Automotive Engineering, Yantai University, Yantai, Shandong, 264005, China.
  • Department of Chemistry and Biochemistry, Border Biomedical Research Center, Forensic Science, & Environmental Science and Engineering, University of Texas at El Paso, El Paso, TX, 79968, USA.
  • Department of Chemistry and Biochemistry, Border Biomedical Research Center, Forensic Science, & Environmental Science and Engineering, University of Texas at El Paso, El Paso, TX, 79968, USA. xli4@utep.edu.

Förderung

  • Natural Science Foundation of Shandong Province
  • Research Starting Foundation of Yantai University
  • Cancer Prevention and Research Institute of Texas
  • U.S. NIH/NIAID
  • U.S. NSF

Zitieren

APA

Li, H., Liu, J., Li, C., Wang, R., Kannan, S., Li, X., & Fu, G. (2025). Development of a syringe-hosted load-and-read immunoassay device using autoinjected distance readout in paper inserts. Microchimica Acta. https://doi.org/10.1007/s00604-025-07052-w

Vancouver

Li H, Liu J, Li C, Wang R, Kannan S, Li X, et al. Development of a syringe-hosted load-and-read immunoassay device using autoinjected distance readout in paper inserts. Microchimica Acta. 2025. doi:10.1007/s00604-025-07052-w

BibTeX
@article{Li2025,
  author = {Li, Haojie and Liu, Jie and Li, Cuili and Wang, Runze and Kannan, Sapna and Li, XiuJun and Fu, Guanglei},
  title = {Development of a syringe-hosted load-and-read immunoassay device using autoinjected distance readout in paper inserts},
  journal = {Microchimica Acta},
  year = {2025},
  doi = {10.1007/s00604-025-07052-w}
}
Kostenlos starten →