Bimetallic metal–organic frameworks as electrode modifiers for enhanced electrochemical sensing of chloramphenicol
Microchimica Acta · 2025-02 · 192 (2)
DOI: 10.1007/s00604-024-06930-z ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 23.01.2025. Verfasst von Jiazhen Tang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optoelectronic Chemical Materials and Devices of Ministry of Education, College of Optoelectronic Materials and Technology, Jiangha…. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: the Scientific Research Project of Jianghan University of Hubei Province of China, Research Fund of Jianghan University, the Research Start-up Funds of Jianghan University.
Abstract (Originalsprache)
An electrochemical sensor is presented for the detection of the chloramphenicol (CAP) based on a bimetallic MIL-101(Fe/Co) MOF electrocatalyst. The MIL-101(Fe/Co) was prepared by utilizing mixed-valence Fe (III) and Co (II) as metal nodes and terephthalic acid as ligands with a simple hydrothermal method and characterized by SEM, TEM, XRD, FTIR, and XPS. Electrochemical measurements such as electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV), and differential pulse voltammetry (DPV) showed that bimetallic MIL-101(Fe/Co) had the faster electron transfer, larger electroactive area, and higher electrocatalytic activity compared with their monometallic counterparts due to the strong synergistic effect between bimetals. Inspired by these results, the MIL-101(Fe/Co)-based sensor was used to detect CAP. Some experiment parameters of pH, Fe and Co molar ratio, MIL-101(Fe/Co) volume, and DPV quiet time were optimized. The direct reduction mechanism of CAP was verified to involve four electrons and four protons process. Finally, the sensitive and selective CAP detection in the concentration range 1 to 200 μM with a detection limit of 0.3 μM was realized by the proposed sensor. The satisfactory recoveries in tap water and lake water indicated the practicability of the proposed electrochemical sensor. It is expected that this work may open up a paradigm for the preparation of MOF-based electrode modifiers with desired electrocatalytic performance for environmental pollution monitoring.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Laboratory of Optoelectronic Chemical Materials and Devices of Ministry of Education, College of Optoelectronic Materials and Technology, Jianghan University, Wuhan, 430056, China.
- Key Laboratory of Optoelectronic Chemical Materials and Devices of Ministry of Education, College of Optoelectronic Materials and Technology, Jianghan University, Wuhan, 430056, China. pengxl0212@163.com.
- Key Laboratory of Optoelectronic Chemical Materials and Devices of Ministry of Education, College of Optoelectronic Materials and Technology, Jianghan University, Wuhan, 430056, China. yazhenwang@163.com.
Förderung
- the Scientific Research Project of Jianghan University of Hubei Province of China
- Research Fund of Jianghan University
- the Research Start-up Funds of Jianghan University
- Hubei Provincial Science and Technology Innovation Talent Plan Project
- Excellent Discipline Cultivation Project by JHUN
Zitieren
APA
Tang, J., Chen, J., Xu, R., Xu, J., Peng, X., & Wang, Y. (2025). Bimetallic metal–organic frameworks as electrode modifiers for enhanced electrochemical sensing of chloramphenicol. Microchimica Acta, 192(2). https://doi.org/10.1007/s00604-024-06930-z
Vancouver
Tang J, Chen J, Xu R, Xu J, Peng X, Wang Y. Bimetallic metal–organic frameworks as electrode modifiers for enhanced electrochemical sensing of chloramphenicol. Microchimica Acta. 2025;192(2). doi:10.1007/s00604-024-06930-z
BibTeX
@article{Tang2025,
author = {Tang, Jiazhen and Chen, Jiawei and Xu, Ruijie and Xu, Junhui and Peng, Xiaolun and Wang, Yazhen},
title = {Bimetallic metal–organic frameworks as electrode modifiers for enhanced electrochemical sensing of chloramphenicol},
journal = {Microchimica Acta},
year = {2025},
volume = {192},
number = {2},
doi = {10.1007/s00604-024-06930-z}
}
EUVIMED