EUVIMEDEUVIMED entdecken
Crossref

Enhanced Alzheimer's biomarker detection using a ternary composite electrochemical aptasensor

Zelong Fan, Lingling Yuan, Tingcheng Xia, Chengxian Zhao, Wenjuan Guo, Ahmed A Ibrahim, Sajid Ali Ansari, Ahmad Umar

Microchimica Acta · 2025-03 · 192 (3)

DOI: 10.1007/s00604-024-06927-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 16.02.2025. Verfasst von Zelong Fan und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, China. Hauptthemen laut MEDLINE: Alzheimer Disease, Aptamers, Nucleotide, Electrochemical Techniques, Amyloid beta-Peptides. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 80 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The development of a highly sensitive electrochemical aptasensor is reported that combines the unique properties of graphene, metallic oxides, and conducting polymers to overcome the limitations of sensitivity and specificity required for early diagnosis of Alzheimer's desease (AD). The sensor design utilizes a ternary composite of polypyrrole (PPy), reduced graphene oxide (rGO), and Fe₂O₃ nanoparticles, which synergistically enhance signal amplification, conductivity, and biocompatibility. The aptasensor leverages aptamers as biorecognition elements for the specific detection of Aβ1-40 oligomers. Electrochemical techniques, including cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS), were employed to characterize and evaluate the sensor's performance. The fabricated aptasensor demonstrated an extraordinary detection limit of 40 fM and a broad linear detection range from 0.1 pM to 200 nM, with exceptional sensitivity and selectivity. Furthermore, the sensor exhibited excellent reproducibility and stability, essential for real-world clinical applications. Real-sample testing using artificial serum further validated the aptasensor's reliability, showcasing its potential for early diagnosis and monitoring of AD. The robust platform and modular design of the sensor also pave the way for its adaptation to detect other target biomolecules by simply modifying the aptamer. This work represents a significant advancement in biosensor technology, offering a versatile, highly sensitive tool for biomedical diagnostics and personalized medicine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Alzheimer DiseaseAptamers, NucleotideElectrochemical TechniquesAmyloid beta-PeptidesBiosensing TechniquesPeptide FragmentsHumansGraphitePyrrolesBiomarkersLimit of DetectionPolymersReproducibility of Results

Stichwörter der Autor:innen

Alzheimer's diseaseAptasensorAβ1-40 oligomersCVConducting polymersDPVEISGrapheneMetallic oxidesModified glassy carbon electrode

Substanzen

Aptamers, NucleotideGraphitePyrrolespolypyrroleAmyloid beta-Peptidesgraphene oxideBiomarkersPolymersPeptide Fragmentsamyloid beta-protein (1-40)

Autor:innen und Institutionen

  • School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, China.
  • Shandong Labor Vocational and Technical College, Jinan, 250022, China.
  • School of Chemistry and Chemical Engineering, University of Jinan, Jinan, 250022, China. chm_guowj@ujn.edu.cn.
  • Department of Chemistry, Faculty of Science and Arts, Promising Centre for Sensors and Electronic Devices, Najran University, Najran, 11001, Kingdom of Saudi Arabia.
  • STEM Pioneers Training Lab, Najran University, Najran, 11001, Kingdom of Saudi Arabia.
  • Department of Physics, College of Science, King Faisal University, P.O. Box 400, 31982, Al-Ahsa, Saudi Arabia.

Zitieren

APA

Fan, Z., Yuan, L., Xia, T., Zhao, C., Guo, W., Ibrahim, A. A., Ansari, S. A., & Umar, A. (2025). Enhanced Alzheimer's biomarker detection using a ternary composite electrochemical aptasensor. Microchimica Acta, 192(3). https://doi.org/10.1007/s00604-024-06927-8

Vancouver

Fan Z, Yuan L, Xia T, Zhao C, Guo W, Ibrahim AA, et al. Enhanced Alzheimer's biomarker detection using a ternary composite electrochemical aptasensor. Microchimica Acta. 2025;192(3). doi:10.1007/s00604-024-06927-8

BibTeX
@article{Fan2025,
  author = {Fan, Zelong and Yuan, Lingling and Xia, Tingcheng and Zhao, Chengxian and Guo, Wenjuan and Ibrahim, Ahmed A and Ansari, Sajid Ali and Umar, Ahmad},
  title = {Enhanced Alzheimer's biomarker detection using a ternary composite electrochemical aptasensor},
  journal = {Microchimica Acta},
  year = {2025},
  volume = {192},
  number = {3},
  doi = {10.1007/s00604-024-06927-8}
}
Kostenlos starten →