An electrochemiluminescence biosensor based on silver-cysteine nanorod as an emitter and AgNP-decorated FeMoOν as a signal amplifier for sensitive detection of heart-type fatty acid binding protein
Microchimica Acta · 2025-01 · 192 (1)
DOI: 10.1007/s00604-024-06923-y ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 30.12.2024. Verfasst von Lingling Zheng und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Key Laboratory for Chemistry and Molecular Engineering of Medici…. Hauptthemen laut MEDLINE: Cysteine, Silver, Nanotubes, Biosensing Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Guangxi Science Foundation of China.
Abstract (Originalsprache)
An electrochemiluminescence (ECL) immunosensor was developed for the highly sensitive and specific detection of heart-type fatty acid binding protein (H-FABP) and the rapid diagnosis of acute myocardial infarction (AMI). H-FABP is a biomarker that is highly specific to cardiac tissue and is associated with a range of cardiac diseases. Following myocardial injury, the rate of increase in H-FABP levels is greater than that observed for myoglobin and troponin. Therefore, the measurement of H-FABP is crucial for the early exclusion of AMI. Silver-cysteine nanorod (AgCysNR), which served as the ECL emitter, was produced with a one-step, green, simple, template-free aqueous phase method. The surfaces of AgCysNR displayed many amino and carboxyl groups that were connected to a large number of a secondary H-FABP-specific antibody. Ferrum-doped molybdenum oxide (FeMoOν), with a large specific surface area, was richly decorated with silver nanoparticle (AgNP), which increased the interfacial electron transfer rate of FeMoOν. The AgNP was used as a co-reaction accelerator to promote persulfate to produce more sulfate anion radical and then enhance the ECL intensity of AgCysNR. The linear range of the ECL immunosensor was 10 fg/mL to 100 ng/mL, and the detection limit was 2.3 fg/mL (signal/noise = 3). The sensor was determined to be stable, repeatable, and reproducible, and the method achieved recoveries of 101.0 to 102.6% with relative standard deviations of 1.4 to 2.0%. This immunosensor represents a promising tool for the early diagnosis of AMI.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources, Key Laboratory for Chemistry and Molecular Engineering of Medicinal Resources (Ministry of Education of China), Collaborative Innovati…
Förderung
- National Natural Science Foundation of China
- Guangxi Science Foundation of China
Zitieren
APA
Zheng, L., Li, J., Hu, S., Xu, L., Wu, Y., & Deng, B. (2025). An electrochemiluminescence biosensor based on silver-cysteine nanorod as an emitter and AgNP-decorated FeMoOν as a signal amplifier for sensitive detection of heart-type fatty acid binding protein. Microchimica Acta, 192(1). https://doi.org/10.1007/s00604-024-06923-y
Vancouver
Zheng L, Li J, Hu S, Xu L, Wu Y, Deng B. An electrochemiluminescence biosensor based on silver-cysteine nanorod as an emitter and AgNP-decorated FeMoOν as a signal amplifier for sensitive detection of heart-type fatty acid binding protein. Microchimica Acta. 2025;192(1). doi:10.1007/s00604-024-06923-y
BibTeX
@article{Zheng2025,
author = {Zheng, Lingling and Li, Jing and Hu, Shenglan and Xu, Lixin and Wu, Yusheng and Deng, Biyang},
title = {An electrochemiluminescence biosensor based on silver-cysteine nanorod as an emitter and AgNP-decorated FeMoOν as a signal amplifier for sensitive detection of heart-type fatty acid binding protein},
journal = {Microchimica Acta},
year = {2025},
volume = {192},
number = {1},
doi = {10.1007/s00604-024-06923-y}
}
EUVIMED