Development of a µPAD for the point-of-care testing of serum glutamic oxaloacetic transaminase (SGOT)
Microchimica Acta · 2024
DOI: 10.1007/s00604-024-06678-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2024. Verfasst von P E Resmi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Amrita School of Physical Sciences Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, 641112, India. Hauptthemen laut MEDLINE: Aspartate Aminotransferases, Point-of-Care Testing, Colorimetry. Die Arbeit nennt 42 Literaturangaben. Gefördert von: Department of Biotechnology (DBT), India.
Abstract (Originalsprache)
A wax-patterned paper analytical device (µPAD) has been developed for point-of-care colourimetric testing of serum glutamic oxaloacetic transaminase (SGOT). The detection method was based on the transamination reaction of aspartate with α-ketoglutarate, leading to the formation of oxaloacetate which reacts with the reagent Fast Blue BB salt and forms a cavern pink colour. The intensity of the cavern pink colour grows as the concentration of SGOT increases. UV-visible spectroscopy was utilized to optimize reaction conditions, and the optimized reagents were dropped onto the wax-patterned paper. The coloured PADs, after the addition of SGOT, have been photographed, and a colour band has been generated to correlate the SGOT concentration visually. The images were used to calculate the intensity values using ImageJ software, which inturn was used to calculate the SGOT concentration. The PADs were also tested with serum samples, and SGOT spiked serum samples. The PAD could detect the SGOT concentration ranging from 5 to 200 U/L. The analysis yielded highly accurate results with less than 6% relative error compared to the clinical sample. This colourimetric test demonstrated exceptional selectivity in the presence of other biomolecules in the blood serum, with a detection limit of 2.77 U/L and a limit of quantification of 9.25 U/L. Additionally, a plasma separation membrane was integrated with the PAD to directly test SGOT from finger-prick blood samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Amrita School of Physical Sciences Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, 641112, India.
- Amrita Biosensor Research Lab, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, 641112, India.
- Amrita School of Biotechnology Amritapuri, Amrita Vishwa Vidyapeetham, Kollam, 690525, India.
- Department of Chemistry, Amrita School of Physical Sciences Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, 641112, India. tgsatheesh@gmail.com.
- Amrita Biosensor Research Lab, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, 641112, India. tgsatheesh@gmail.com.
- Amrita Biomedical Engineering Centre, Amrita School of Engineering Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, 641112, India. tgsatheesh@gmail.com.
Förderung
- Department of Biotechnology (DBT), India
Zitieren
APA
Resmi, P. E., Aarathi, P., Suneesh, P. V., Ramachandran, T., Bipin, G. N., & Satheesh, B. T. G. (2024). Development of a µPAD for the point-of-care testing of serum glutamic oxaloacetic transaminase (SGOT). Microchimica Acta. https://doi.org/10.1007/s00604-024-06678-6
Vancouver
Resmi PE, Aarathi P, Suneesh PV, Ramachandran T, Bipin GN, Satheesh BTG. Development of a µPAD for the point-of-care testing of serum glutamic oxaloacetic transaminase (SGOT). Microchimica Acta. 2024. doi:10.1007/s00604-024-06678-6
BibTeX
@article{Resmi2024,
author = {Resmi, P E and Aarathi, Pradeep and Suneesh, P V and Ramachandran, T and Bipin, G Nair and Satheesh, Babu T G},
title = {Development of a µPAD for the point-of-care testing of serum glutamic oxaloacetic transaminase (SGOT)},
journal = {Microchimica Acta},
year = {2024},
doi = {10.1007/s00604-024-06678-6}
}
EUVIMED