The portable stochastic sensor as a screening tool for simultaneous determination of HER-1 and CA 125 — a key factor in the rapid recognition of gastric cancer
Microchimica Acta · 2024
DOI: 10.1007/s00604-024-06674-w ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2024. Verfasst von Ionela Raluca Comnea-Stancu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Electrochemistry and PATLAB, National Institute of Research and Development for Electrochemistry and Condensed Matter, 202 Splaiul Inde…. Hauptthemen laut MEDLINE: CA-125 Antigen, Stomach Neoplasms, Titanium, Gold. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Unitatea Executiva pentru Finantarea Invatamantului Superior, a Cercetarii, Dezvoltarii si Inovarii.
Abstract (Originalsprache)
The significance of HER-1 and CA 125 lies in their ability to guide cancer diagnosis, treatment, and monitoring, improving personalized care and enhancing prognostic accuracy. The utilization of HER-1 and CA 125 as screening biomarkers for the anticipation of early-stage cancer and monitoring cancer progression is expanding due to the invasive and costly nature of present techniques. In this study, a novel stochastic sensor was developed for the simultaneous determination of HER-1 and CA 125 in whole blood, saliva, and gastric tumor tissue samples using a fast, easy, inexpensive, and portable method. The stochastic sensor was prepared by electropolymerization of cysteine on the surface of the Au-TiO2@rGO/SPCE sensor. The Au-TiO2@rGO nanocomposite was synthesized using a simple chemical reduction process. The proposed sensor showed wide linear concentration ranges and very low limits of quantification (LOQ). The concentration ranges were from 3.9 × 10-14 to 3.9 × 10-8 µg mL-1, with a LOQ of 3.9 × 10-14 µg mL-1 for HER-1. For CA 125, the concentration ranges were from 8.3 × 10-14 to 8.3 × 10-10 U mL-1, with a LOQ of 8.3 × 10-14 U mL-1. Both biomarkers exhibit precise discrimination in different biological samples, with recoveries above 96.78% and RSD values below 0.04%. With a confidence level of 99%, the Student t-test revealed that there is no statistically significant difference between the outcomes obtained by using the poly-Cys/Au-TiO2@rGO/SPCE sensor for screening examinations of biological samples. This was determined because the results were not significantly different from one another.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Laboratory of Electrochemistry and PATLAB, National Institute of Research and Development for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Street, 060021, Bucharest, Romania.
- "Ilie Murgulescu" Institute of Physical Chemistry of the Romanian Academy, 202 Splaiul Independentei Street, 060021, Bucharest, Romania.
- Laboratory of Electrochemistry and PATLAB, National Institute of Research and Development for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Street, 060021, Bucharest, Romania. i.ruxandra04@yahoo.com.
Förderung
- Unitatea Executiva pentru Finantarea Invatamantului Superior, a Cercetarii, Dezvoltarii si Inovarii
Zitieren
APA
Comnea-Stancu, I. R., Georgescu-State, R., Stefan-van Staden, R. I., State, R. N., & Ilie-Mihai, R. M. (2024). The portable stochastic sensor as a screening tool for simultaneous determination of HER-1 and CA 125 — a key factor in the rapid recognition of gastric cancer. Microchimica Acta. https://doi.org/10.1007/s00604-024-06674-w
Vancouver
Comnea-Stancu IR, Georgescu-State R, Stefan-van Staden RI, State RN, Ilie-Mihai RM. The portable stochastic sensor as a screening tool for simultaneous determination of HER-1 and CA 125 — a key factor in the rapid recognition of gastric cancer. Microchimica Acta. 2024. doi:10.1007/s00604-024-06674-w
BibTeX
@article{ComneaStancu2024,
author = {Comnea-Stancu, Ionela Raluca and Georgescu-State, Ramona and Stefan-van Staden, Raluca-Ioana and State, Razvan Nicolae and Ilie-Mihai, Ruxandra-Maria},
title = {The portable stochastic sensor as a screening tool for simultaneous determination of HER-1 and CA 125 — a key factor in the rapid recognition of gastric cancer},
journal = {Microchimica Acta},
year = {2024},
doi = {10.1007/s00604-024-06674-w}
}
EUVIMED