EUVIMEDEUVIMED entdecken
Crossref

Smartphone-assisted ratiometric fluorescent sensor to quantitatively detect curcumin in traditional Chinese medicine based on Förster resonance energy transfer

Shuang Wu, Yunhan Wang, Shikai Han, Ge Hui, Ye Teng, Wei Liu, Yu Zhao

Microchimica Acta · 2024

DOI: 10.1007/s00604-024-06670-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2024. Verfasst von Shuang Wu und 6 weiteren Autor:innen. Beteiligte Einrichtung: Jilin Ginseng Academy, Changchun University of Chinese Medicine, Changchun, 130017, China. Hauptthemen laut MEDLINE: Curcumin, Fluorescence Resonance Energy Transfer, Smartphone, Fluorescent Dyes. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: The project was supported by the science and technology research project of education Department of Jilin Province, Provincial Innovation Training Program for College Students.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A ratiometric fluorescence sensor (Fe-MIL-88-NH2/curcumin) based on luminescent metal-organic frameworks (LMOFs) for the determination of curcumin was constructed. Upon the addition of curcumin, the 535-nm emission of curcumin was enhanced, while the fluorescence emission at 438 nm was quenched, under 367-nm excitation. This sensor demonstrated a broad linear range from 1.5 to 40 μM, a low detection limit of 35 nM, and a fast response time of at most 30 s. We verified the Förster resonance energy transfer (FRET) mechanism between donor (Fe-MIL-88-NH2) and acceptor (curcumin), which further proved the selectivity of the approach. The sensing system enabled the detection of curcumin in the traditional Chinese medicine (TCM) Turmeric. A smartphone-assisted sensing platform was prepared to visually detect curcumin in a portable manner. This study represents the first attempt to fabricate LMOFs for ratiometric fluorescence detection of curcumin, which has promising potential for application in TCM.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CurcuminFluorescence Resonance Energy TransferSmartphoneFluorescent DyesLimit of DetectionMetal-Organic FrameworksMedicine, Chinese TraditionalCurcumaDrugs, Chinese Herbal

Stichwörter der Autor:innen

CurcuminFe-MIL-88-NH2Förster resonance energy transfer,Ratiometric fluorescenceSmartphone assisted visual sensing platform

Substanzen

CurcuminFluorescent DyesMetal-Organic FrameworksDrugs, Chinese Herbal

Autor:innen und Institutionen

  • Jilin Ginseng Academy, Changchun University of Chinese Medicine, Changchun, 130017, China.
  • College of Pharmacy, Changchun University of Chinese Medicine, Changchun, 130017, China.
  • College of Pharmacy, Changchun University of Chinese Medicine, Changchun, 130017, China. liuwei_cczyydx@163.com.
  • Jilin Ginseng Academy, Changchun University of Chinese Medicine, Changchun, 130017, China. cnzhaoyu1972@162.com.

Förderung

  • The project was supported by the science and technology research project of education Department of Jilin Province
  • Provincial Innovation Training Program for College Students

Zitieren

APA

Wu, S., Wang, Y., Han, S., Hui, G., Teng, Y., Liu, W., & Zhao, Y. (2024). Smartphone-assisted ratiometric fluorescent sensor to quantitatively detect curcumin in traditional Chinese medicine based on Förster resonance energy transfer. Microchimica Acta. https://doi.org/10.1007/s00604-024-06670-0

Vancouver

Wu S, Wang Y, Han S, Hui G, Teng Y, Liu W, et al. Smartphone-assisted ratiometric fluorescent sensor to quantitatively detect curcumin in traditional Chinese medicine based on Förster resonance energy transfer. Microchimica Acta. 2024. doi:10.1007/s00604-024-06670-0

BibTeX
@article{Wu2024,
  author = {Wu, Shuang and Wang, Yunhan and Han, Shikai and Hui, Ge and Teng, Ye and Liu, Wei and Zhao, Yu},
  title = {Smartphone-assisted ratiometric fluorescent sensor to quantitatively detect curcumin in traditional Chinese medicine based on Förster resonance energy transfer},
  journal = {Microchimica Acta},
  year = {2024},
  doi = {10.1007/s00604-024-06670-0}
}
Kostenlos starten →