EUVIMEDEUVIMED entdecken
Crossref

Natural deep eutectic solvent–functionalized mesoporous graphitic carbon nitride–reinforced electrospun nanofiber: a promising sorbent in miniaturized on-chip thin film micro-solid-phase extraction prior to liquid chromatography–tandem mass spectrometry for measuring NSAIDs in saliva

Mahsa Shirkhodaie, Shahram Seidi, Farzaneh Shemirani, Farnaz Zaroudi, Nasim Madadkar

Microchimica Acta · 2024

DOI: 10.1007/s00604-024-06650-4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2024. Verfasst von Mahsa Shirkhodaie und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry, College of Science, University of Tehran, P.O. Box 14155-6455, Tehran, Iran. Hauptthemen laut MEDLINE: Saliva, Tandem Mass Spectrometry, Graphite, Nanofibers. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 49 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To meet the needs of developing efficient extractive materials alongside the evolution of miniaturized sorbent-based sample preparation techniques, a mesoporous structure of g-C3N4 doped with sulfur as a heteroatom was achieved utilizing a bubble template approach while avoiding the severe conditions of other methods. In an effort to increase the number of adsorption sites, the resultant exfoliated structure was then modified with thymol-coumarin NADES as a natural sorbent modifier, followed by introduction into a nylon 6 polymer via an electrospinning process. X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy, field-emission scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and Brunauer-Emmett-Teller (BET) surface area analysis validated S-doped g-C3N4 and composite production. The prepared electrospun fiber nanocomposite, entailing satisfactory processability, was then successfully utilized as a sorbent in on-chip thin film micro-solid-phase extraction of non-steroidal anti-inflammatory drugs (NSAIDs) from saliva samples prior to liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis. Utilizing a chip device, a thin film μ-SPE coupled with LC-MS/MS analysis yielded promising outcomes with reduced sample solution and organic solvents while extending lifetime of a thin film sorbent. The DES-modified S-doped g-C3N4 amount in electrospun was optimized, along with adsorption and desorption variables. Under optimal conditions, selected NSAIDs were found to have a linear range of 0.05-100.0 ng mL-1 with an R2 ≥ 0.997. The detection limits were ranged between 0.02 and 0.2 ng mL-1. The intra-day and inter-day precisions obtained were less than 6.0%. Relative recoveries were between 93.3 and 111.4%.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SalivaTandem Mass SpectrometryGraphiteNanofibersAnti-Inflammatory Agents, Non-SteroidalLimit of DetectionDeep Eutectic SolventsHumansAdsorptionPorosityChromatography, LiquidNitrogen CompoundsSolid Phase MicroextractionSolid Phase Extraction

Stichwörter der Autor:innen

Electrospun composite nanofiberGraphitic carbon nitrideMesoporous adsorptiveNatural deep eutectic solventOn-chip thin film micro-solid-phase extraction

Substanzen

Graphitegraphitic carbon nitrideAnti-Inflammatory Agents, Non-SteroidalDeep Eutectic SolventsNitrogen Compounds

Autor:innen und Institutionen

  • School of Chemistry, College of Science, University of Tehran, P.O. Box 14155-6455, Tehran, Iran.
  • Nanomaterial, Separation and Trace Analysis Research Lab, K.N, Toosi University of Technology, P.O. Box 16315-1618, Tehran, 15418-49611, Iran. s.seidi@kntu.ac.ir.
  • School of Chemistry, College of Science, University of Tehran, P.O. Box 14155-6455, Tehran, Iran. fashemirani@ut.ac.ir.
  • Department of Analytical Chemistry, Faculty of Chemistry, K.N, Toosi University of Technology, P.O. Box 16315-1618, Tehran, 15418-49611, Iran.
  • Nanomaterial, Separation and Trace Analysis Research Lab, K.N, Toosi University of Technology, P.O. Box 16315-1618, Tehran, 15418-49611, Iran.

Zitieren

APA

Shirkhodaie, M., Seidi, S., Shemirani, F., Zaroudi, F., & Madadkar, N. (2024). Natural deep eutectic solvent–functionalized mesoporous graphitic carbon nitride–reinforced electrospun nanofiber: a promising sorbent in miniaturized on-chip thin film micro-solid-phase extraction prior to liquid chromatography–tandem mass spectrometry for measuring NSAIDs in saliva. Microchimica Acta. https://doi.org/10.1007/s00604-024-06650-4

Vancouver

Shirkhodaie M, Seidi S, Shemirani F, Zaroudi F, Madadkar N. Natural deep eutectic solvent–functionalized mesoporous graphitic carbon nitride–reinforced electrospun nanofiber: a promising sorbent in miniaturized on-chip thin film micro-solid-phase extraction prior to liquid chromatography–tandem mass spectrometry for measuring NSAIDs in saliva. Microchimica Acta. 2024. doi:10.1007/s00604-024-06650-4

BibTeX
@article{Shirkhodaie2024,
  author = {Shirkhodaie, Mahsa and Seidi, Shahram and Shemirani, Farzaneh and Zaroudi, Farnaz and Madadkar, Nasim},
  title = {Natural deep eutectic solvent–functionalized mesoporous graphitic carbon nitride–reinforced electrospun nanofiber: a promising sorbent in miniaturized on-chip thin film micro-solid-phase extraction prior to liquid chromatography–tandem mass spectrometry for measuring NSAIDs in saliva},
  journal = {Microchimica Acta},
  year = {2024},
  doi = {10.1007/s00604-024-06650-4}
}
Kostenlos starten →