Signal-amplified surface-enhanced Raman scattering using core/shell satellite nanoparticles for norovirus detection
Microchimica Acta · 2024
DOI: 10.1007/s00604-024-06600-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2024. Verfasst von Enoch Y Park und 3 weiteren Autor:innen. Beteiligte Einrichtung: Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya Suruga-Ku, Shizuoka, 422-8529, Japan. park.enoch@shizuoka.ac.jp. Hauptthemen laut MEDLINE: Spectrum Analysis, Raman, Norovirus, Metal Nanoparticles, Gold. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
The development of an innovative approach is explored to amplify the signal of a surface-enhanced Raman scattering (SERS)-based detection system using a novel nanotag: Au@Ag NPs covered by satellite AuNPs and conjugated by 4-mercaptbenzoic acid (4-MBA) as a Raman tag (Au@Ag-MBA-AuNPs). The Au@Ag-MBA-AuNPs nanotags showed strong SERS activities with an enhancement factor in the 108 order of magnitude. This indicates the formation of many hot spots due to the combination of core-shell nanoparticles and satellite AuNPs on the surface of Au@Ag-MBA NPs. The newly fabricated nanotags were employed in a small-sized Palmtop Raman spectrometer. A concentration-dependent increase in SERS intensity was observed in the norovirus-like particle (NoV-LP) concentration range 10 fg/mL to 100 pg/mL with a detection limit of 0.76 fg/mL. Even in the severe interfering matrices, this detection method's coefficient of variation was less than 10%. This detection system was approximately 107 times more sensitive than commercially available ELISA kits. Norovirus in clinical samples was detected over a wide concentration range of 1.0 × 101 - 1.0 × 106 RNA copy number/mL with a detection limit of 7.8 RNA copy number/mL, indicating sensitivity comparable to real-time PCR. These results suggest that this detection system is stable in a complex matrix and has the potential for detecting norovirus in clinical samples with a small Palmtop Raman spectrometer.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya Suruga-Ku, Shizuoka, 422-8529, Japan. park.enoch@shizuoka.ac.jp.
- Graduate School of Integrated Science and Technology, Shizuoka University, 836 Ohya Suruga-Ku, Shizuoka, 422-8529, Japan. park.enoch@shizuoka.ac.jp.
- Faculty of Agriculture, Shizuoka University, 836 Ohya Suruga-Ku, Shizuoka, 422-8529, Japan. park.enoch@shizuoka.ac.jp.
- Graduate School of Integrated Science and Technology, Shizuoka University, 836 Ohya Suruga-Ku, Shizuoka, 422-8529, Japan.
- Research Institute of Green Science and Technology, Shizuoka University, 836 Ohya Suruga-Ku, Shizuoka, 422-8529, Japan.
- National Institute Advanced Industrial Science and Technology (AIST), Tsukuba, Ibaraki, 305-8565, Japan.
Zitieren
APA
Park, E. Y., Maehata, S., Khoris, I. M., & Achadu, O. J. (2024). Signal-amplified surface-enhanced Raman scattering using core/shell satellite nanoparticles for norovirus detection. Microchimica Acta. https://doi.org/10.1007/s00604-024-06600-0
Vancouver
Park EY, Maehata S, Khoris IM, Achadu OJ. Signal-amplified surface-enhanced Raman scattering using core/shell satellite nanoparticles for norovirus detection. Microchimica Acta. 2024. doi:10.1007/s00604-024-06600-0
BibTeX
@article{Park2024,
author = {Park, Enoch Y and Maehata, Syuei and Khoris, Indra Memdi and Achadu, Ojodomo J},
title = {Signal-amplified surface-enhanced Raman scattering using core/shell satellite nanoparticles for norovirus detection},
journal = {Microchimica Acta},
year = {2024},
doi = {10.1007/s00604-024-06600-0}
}