Solid electrochemiluminescence sensor by immobilization luminol in Zn-Co-ZIF CNFs for sensitive detection of procymidone in vegetables
Microchimica Acta · 2024
DOI: 10.1007/s00604-024-06582-z ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2024. Verfasst von Juan Lu und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry, Changchun Normal University, Changchun, 130032, P.R. China. lujuan1982cc@163.com. Hauptthemen laut MEDLINE: Luminol, Vegetables, Electrochemical Techniques, Luminescent Measurements. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 30 Literaturangaben.
Abstract (Originalsprache)
A solid-state electrochemiluminescence (ECL) sensor was fabricated by immobilizing luminol, a classical luminescent reagent, on a Zn-Co-ZIF carbon fiber-modified electrode for the rapid and sensitive detection of procymidone (PCM) in vegetable samples. The sensor was created by sequentially modifying the glassy carbon electrode with Zn-Co-ZIF carbon fiber (Zn-Co-ZIF CNFs), Pt@Au NPs, and luminol. Zn-Co-ZIF CNFs, prepared through electrospinning and high-temperature pyrolysis, possessed a large specific surface area and porosity, making it suitable as carrier and electron transfer accelerator in the system. Pt@Au NPs demonstrated excellent catalytic activity, effectively enhancing the generation of active substances. The ECL signal was significantly amplified by the combination of Zn-Co-ZIF CNFs and Pt@Au NPs, which can subsequently be diminished by procymidone. The ECL intensity decreased proportionally with the addition of procymidone, displaying a linear relationship within the concentration range 1.0 × 10-13 to 1.0 × 10-6 mol L-1 (R2 = 0.993). The sensor exhibited a detection limit of 3.3 × 10-14 mol L-1 (S/N = 3) and demonstrated outstanding reproducibility and stability, making it well-suited for the detection of procymidone in vegetable samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Chemistry, Changchun Normal University, Changchun, 130032, P.R. China. lujuan1982cc@163.com.
- Technological Innovation Laboratory for Research and Development of Economic Plants and Edible and Medicinal Fungi in Cold Region of Jilin Province, Changchun, 130032, P.R. China. lujuan1982cc@163.com.
- College of Chemistry, Changchun Normal University, Changchun, 130032, P.R. China.
- College of Chemistry, Jilin University, Changchun, 130022, P.R. China. xwli@jlu.edu.cn.
Zitieren
APA
Lu, J., Guo, Y., Shan, X., Song, Y., Li, R., Tian, L., & Li, X. (2024). Solid electrochemiluminescence sensor by immobilization luminol in Zn-Co-ZIF CNFs for sensitive detection of procymidone in vegetables. Microchimica Acta. https://doi.org/10.1007/s00604-024-06582-z
Vancouver
Lu J, Guo Y, Shan X, Song Y, Li R, Tian L, et al. Solid electrochemiluminescence sensor by immobilization luminol in Zn-Co-ZIF CNFs for sensitive detection of procymidone in vegetables. Microchimica Acta. 2024. doi:10.1007/s00604-024-06582-z
BibTeX
@article{Lu2024,
author = {Lu, Juan and Guo, Yanjia and Shan, Xiangyu and Song, Yujia and Li, Ruidan and Tian, Li and Li, Xuwen},
title = {Solid electrochemiluminescence sensor by immobilization luminol in Zn-Co-ZIF CNFs for sensitive detection of procymidone in vegetables},
journal = {Microchimica Acta},
year = {2024},
doi = {10.1007/s00604-024-06582-z}
}
EUVIMED