EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparative performance analysis of mussel-inspired polydopamine, polynorepinephrine, and poly-α-methyl norepinephrine in electrochemical biosensors

Neha Bisht, Monika Patel, D P Mondal, Avanish Kumar Srivastava, Neeraj Dwivedi, Chetna Dhand

Microchimica Acta · 2024

DOI: 10.1007/s00604-024-06521-y ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Microchimica Acta, 2024. Verfasst von Neha Bisht und 5 weiteren Autor:innen. Beteiligte Einrichtung: CSIR-Advanced Materials and Processes Research Institute, Hoshangabad Road, Bhopal, 462026, India. Hauptthemen laut MEDLINE: Biosensing Techniques, Indoles, Polymers, Electrochemical Techniques. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 87 Literaturangaben. Gefördert von: Focussed Basic Research, Science and Engineering Research Board, Indian Council of Medical Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Polydopamine (PDA) has garnered significant interest for applications in biosensors, drug delivery, and tissue engineering. However, similar polycatecholamines like polynorepinephrine (PNE) with additional hydroxyl groups and poly-α-methylnorepinephrine (PAMN) with additional hydroxyl and methyl groups remain unexplored in the biosensing domain. This research introduces three innovative biosensing platforms composed of ternary nanocomposite based on reduced graphene oxide (RGO), gold nanoparticles (Au NPs), and three sister polycatecholamine compounds (PDA, PNE, and PAMN). The study compares and evaluates the performance of the three biosensing systems for the ultrasensitive detection of Mycobacterium tuberculosis (MTB). The formation of the nanocomposites was meticulously examined through UV-Visible, Raman, XRD, and FT-IR studies with FE-SEM and HR-TEM analysis. Cyclic voltammetry and differential pulse voltammetry measurements were also performed to determine the electrochemical characteristics of the modified electrodes. Electrochemical biosensing experiments reveal that the RGO-PDA-Au, RGO-PNE-Au, and RGO-PAMN-Au-based biosensors detected target DNA up to a broad detection range of 0.1 × 10-8 to 0.1 × 10-18 M, with a low detection limit (LOD) of 0.1 × 10-18, 0.1 × 10-16, and 0.1 × 10-17 M, respectively. The bioelectrodes were proved to be highly selective with excellent sensitivities of 3.62 × 10-4 mA M-1 (PDA), 7.08 × 10-4 mA M-1 (PNE), and 6.03 × 10-4 mA M-1 (PAMN). This study pioneers the exploration of two novel mussel-inspired polycatecholamines in biosensors, opening avenues for functional nanocoatings that could drive further advancements in this field.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesIndolesPolymersElectrochemical TechniquesGraphiteGoldLimit of DetectionMetal NanoparticlesAnimalsMycobacterium tuberculosisBivalviaNanocompositesElectrodesNorepinephrine

Stichwörter der Autor:innen

Mycobacterium tuberculosisDifferential pulse voltammetryElectrochemical biosensorModified electrodePoly-α-methylnorepinephrinePolydopaminePolynorepinephrine

Substanzen

polydopamineIndolesPolymersGraphiteGoldgraphene oxideNorepinephrine

Autor:innen und Institutionen

  • CSIR-Advanced Materials and Processes Research Institute, Hoshangabad Road, Bhopal, 462026, India.
  • Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India.
  • CSIR-Advanced Materials and Processes Research Institute, Hoshangabad Road, Bhopal, 462026, India. neerajdwivedi6@gmail.com.
  • Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India. neerajdwivedi6@gmail.com.
  • CSIR-Advanced Materials and Processes Research Institute, Hoshangabad Road, Bhopal, 462026, India. chetnachem24@gmail.com.
  • Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India. chetnachem24@gmail.com.

Förderung

  • Focussed Basic Research
  • Science and Engineering Research Board
  • Indian Council of Medical Research

Zitieren

APA

Bisht, N., Patel, M., Mondal, D. P., Srivastava, A. K., Dwivedi, N., & Dhand, C. (2024). Comparative performance analysis of mussel-inspired polydopamine, polynorepinephrine, and poly-α-methyl norepinephrine in electrochemical biosensors. Microchimica Acta. https://doi.org/10.1007/s00604-024-06521-y

Vancouver

Bisht N, Patel M, Mondal DP, Srivastava AK, Dwivedi N, Dhand C. Comparative performance analysis of mussel-inspired polydopamine, polynorepinephrine, and poly-α-methyl norepinephrine in electrochemical biosensors. Microchimica Acta. 2024. doi:10.1007/s00604-024-06521-y

BibTeX
@article{Bisht2024,
  author = {Bisht, Neha and Patel, Monika and Mondal, D P and Srivastava, Avanish Kumar and Dwivedi, Neeraj and Dhand, Chetna},
  title = {Comparative performance analysis of mussel-inspired polydopamine, polynorepinephrine, and poly-α-methyl norepinephrine in electrochemical biosensors},
  journal = {Microchimica Acta},
  year = {2024},