Submersible voltammetric sensing probe for rapid and extended remote monitoring of opioids in community water systems
Microchimica Acta · 2024
DOI: 10.1007/s00604-024-06520-z ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2024. Verfasst von Jiachi Zhou und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nanoengineering, University of California San Diego, La Jolla, CA, 92093, USA. Hauptthemen laut MEDLINE: Water Pollutants, Chemical, Electrochemical Techniques, Fentanyl, Analgesics, Opioid. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The intensifying global opioid crisis, majorly attributed to fentanyl (FT) and its analogs, has necessitated the development of rapid and ultrasensitive remote/on-site FT sensing modalities. However, current approaches for tracking FT exposure through wastewater-based epidemiology (WBE) are unadaptable, time-consuming, and require trained professionals. Toward developing an extended in situ wastewater opioid monitoring system, we have developed a screen-printed electrochemical FT sensor and integrated it with a customized submersible remote sensing probe. The sensor composition and design have been optimized to address the challenges for extended in situ FT monitoring. Specifically, ZIF-8 metal–organic framework (MOF)-derived mesoporous carbon (MPC) nanoparticles (NPs) are incorporated in the screen-printed carbon electrode (SPCE) transducer to improve FT accumulation and its electrocatalytic oxidation. A rapid (10 s) and sensitive square wave voltammetric (SWV) FT detection down to 9.9 µgL −1 is thus achieved in aqueous buffer solution. A protective mixed-matrix membrane (MMM) has been optimized as the anti-fouling sensor coating to mitigate electrode passivation by FT oxidation products and enable long-term, intermittent FT monitoring. The unique MMM, comprising an insulating polyvinyl chloride (PVC) matrix and carboxyl-functionalized multi-walled carbon nanotubes (CNT-COOH) as semiconductive fillers, yielded highly stable FT sensor operation (> 95% normalized response) up to 10 h in domestic wastewater, and up to 4 h in untreated river water. This sensing platform enables wireless data acquisition on a smartphone via Bluetooth. Such effective remote operation of submersible opioid sensing probes could enable stricter surveillance of community water systems toward timely alerts, countermeasures, and legal enforcement. Graphical abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, 92093, USA.
- Department of Nanoengineering, University of California San Diego, La Jolla, CA, 92093, USA. josephwang@ucsd.edu.
Zitieren
APA
Zhou, J., Ding, S., Sandhu, S. S., Chang, A. Y., Taechamahaphan, A., Gudekar, S., & Wang, J. (2024). Submersible voltammetric sensing probe for rapid and extended remote monitoring of opioids in community water systems. Microchimica Acta. https://doi.org/10.1007/s00604-024-06520-z
Vancouver
Zhou J, Ding S, Sandhu SS, Chang AY, Taechamahaphan A, Gudekar S, et al. Submersible voltammetric sensing probe for rapid and extended remote monitoring of opioids in community water systems. Microchimica Acta. 2024. doi:10.1007/s00604-024-06520-z
BibTeX
@article{Zhou2024,
author = {Zhou, Jiachi and Ding, Shichao and Sandhu, Samar S and Chang, An-Yi and Taechamahaphan, Anubhap and Gudekar, Shipra and Wang, Joseph},
title = {Submersible voltammetric sensing probe for rapid and extended remote monitoring of opioids in community water systems},
journal = {Microchimica Acta},
year = {2024},
doi = {10.1007/s00604-024-06520-z}
}
EUVIMED