EUVIMEDEUVIMED entdecken
Crossref

Ti3C2/Ni/Sm-based electrochemical glucose sensor for sweat analysis using bipolar electrochemistry

Zahra Damirchi, Ali Firoozbakhtian, Morteza Hosseini, Mohammad Reza Ganjali

Microchimica Acta · 2024-03 · 191 (3)

DOI: 10.1007/s00604-024-06209-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 15.02.2024. Verfasst von Zahra Damirchi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Center of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran, 1439817435, Iran. Hauptthemen laut MEDLINE: Sweat, Titanium, Nitrites, Transition Elements. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: University of Tehran.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An innovative electrochemical sensor is introduced that utilizes bipolar electrochemistry on a paper substrate for detecting glucose in sweat. The sensor employs a three-dimensional porous nanocomposite (MXene/NiSm-LDH) formed by decorating nickel-samarium nanoparticles with double-layer MXene hydroxide. These specially designed electrodes exhibit exceptional electrocatalytic activity during glucose oxidation. The glucose sensing mechanism involves enzyme-free oxidation of the analyte within the sensor cell, achieved by applying an appropriate potential. This leads to the reduction of K3Fe(CN)6 in the reporter cell, and the resulting current serves as the response signal. By optimizing various parameters, the measurement platform enables the accurate determination of sweat glucose concentrations within a linear range of 10 to 200 µM. The limit of detection (LOD) for glucose is 3.6 µM (S/N = 3), indicating a sensitive and reliable detection capability. Real samples were analysed to validate the sensor's efficiency, and the results obtained were both promising and encouraging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SweatTitaniumNitritesTransition ElementsElectrochemistryGlucose

Stichwörter der Autor:innen

Bipolar electrochemistryEnzyme-freeGlucoseMXeneScreen-printed electrodeSweat analysis

Substanzen

MXeneTitaniumGlucoseNitritesTransition Elements

Autor:innen und Institutionen

  • Center of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran, 1439817435, Iran.
  • Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, 1439817435, Iran.
  • Nanobiosensors Lab, Department of Life Science Engineering, Faculty of New Sciences & Technologies, University of Tehran, Tehran, 1439817435, Iran. Hosseini_m@ut.ac.ir.
  • Medical Genetics Department, Institute of Medical Biotechnology (IMB), National Institute of Genetic Engineering and Biotechnology (NIGEB), Tehran, Iran. Hosseini_m@ut.ac.ir.
  • Center of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran, 1439817435, Iran. ganjali@ut.ac.ir.

Förderung

  • University of Tehran

Zitieren

APA

Damirchi, Z., Firoozbakhtian, A., Hosseini, M., & Ganjali, M. R. (2024). Ti3C2/Ni/Sm-based electrochemical glucose sensor for sweat analysis using bipolar electrochemistry. Microchimica Acta, 191(3). https://doi.org/10.1007/s00604-024-06209-3

Vancouver

Damirchi Z, Firoozbakhtian A, Hosseini M, Ganjali MR. Ti3C2/Ni/Sm-based electrochemical glucose sensor for sweat analysis using bipolar electrochemistry. Microchimica Acta. 2024;191(3). doi:10.1007/s00604-024-06209-3

BibTeX
@article{Damirchi2024,
  author = {Damirchi, Zahra and Firoozbakhtian, Ali and Hosseini, Morteza and Ganjali, Mohammad Reza},
  title = {Ti3C2/Ni/Sm-based electrochemical glucose sensor for sweat analysis using bipolar electrochemistry},
  journal = {Microchimica Acta},
  year = {2024},
  volume = {191},
  number = {3},
  doi = {10.1007/s00604-024-06209-3}
}
Kostenlos starten →