Core–shell “loading-type” nanomaterials enabling glucometer readout for portable and sensitive detection of p-aminophenol in real samples
Microchimica Acta · 2024
DOI: 10.1007/s00604-024-06204-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2024. Verfasst von Xiang-Ling Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Materials-Oriented Chemical Engineering, Nanjing Tech University, Nanjing, 211816, People's Republic of China. Hauptthemen laut MEDLINE: Oxides, Nanostructures, Aminophenols. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: the National Key Research and Development Program of China, National Natural Science Foundation of China, Natural Science Foundation of Jiangsu Province.
Abstract (Originalsprache)
A one-target-many-trigger signal model sensing strategy is proposed for quickly, sensitive and on-site detection of the environmental pollutant p-aminophenol (PAP) by use of a commercial personal glucose meter (PGM) for signal readout with the core-shell "loading-type" nanomaterial MSNs@MnO2 as amplifiable nanoprobes. In this design, the mesoporous silica nanoparticles (MSNs) nanocontainer with entrapped signal molecule glucose is coated with redoxable manganese dioxide (MnO2) nanosheets to form the amplifiable nanoprobes (Glu-MSNs@MnO2). When encountered with PAP, the redox reaction between the MnO2 and PAP can induce the degradation of the outer layer of MSNs@MnO2, liberating multiple copies of the loaded glucose to light up the PGM signal. Owing to the high loading capability of nanocarriers, a "one-to-many" relationship exists between the target and the signal molecule glucose, which can generate adequate signal outputs to achieve the requirement of on-site determination of environmental pollutants. Taking advantage of this amplification mode, the developed PAP assay owns a dynamic linear range of 10.0-400 μM with a detection limit of 2.78 μM and provides good practical application performance with above 96.7 ± 4.83% recovery in environmental water and soil samples. Therefore, the PGM-based amplifiable sensor for PAP proposed can accommodate these requirements of environment monitoring and has promising potential for evaluating pollutants in real environmental samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Materials-Oriented Chemical Engineering, Nanjing Tech University, Nanjing, 211816, People's Republic of China.
- College of Biotechnology and Pharmaceutical Engineering, Nanjing Tech University, Nanjing, 211816, People's Republic of China.
- Jiangsu Academy of Agricultural Sciences, Nanjing, 210014, People's Republic of China. guoting@hotmail.com.
- State Key Laboratory of Materials-Oriented Chemical Engineering, Nanjing Tech University, Nanjing, 211816, People's Republic of China. xiej@njtech.edu.cn.
- College of Biotechnology and Pharmaceutical Engineering, Nanjing Tech University, Nanjing, 211816, People's Republic of China. xiej@njtech.edu.cn.
Förderung
- the National Key Research and Development Program of China
- National Natural Science Foundation of China
- Natural Science Foundation of Jiangsu Province
- Jiangsu Provincial Key Research and Development Program
Zitieren
APA
Li, X. L., Zhao, L., Wang, Z. H., Song, T. S., Guo, T., & Xie, J. J. (2024). Core–shell “loading-type” nanomaterials enabling glucometer readout for portable and sensitive detection of p-aminophenol in real samples. Microchimica Acta. https://doi.org/10.1007/s00604-024-06204-8
Vancouver
Li XL, Zhao L, Wang ZH, Song TS, Guo T, Xie JJ. Core–shell “loading-type” nanomaterials enabling glucometer readout for portable and sensitive detection of p-aminophenol in real samples. Microchimica Acta. 2024. doi:10.1007/s00604-024-06204-8
BibTeX
@article{Li2024,
author = {Li, Xiang-Ling and Zhao, Lei and Wang, Zi-Heng and Song, Tian-Shun and Guo, Ting and Xie, Jing Jing},
title = {Core–shell “loading-type” nanomaterials enabling glucometer readout for portable and sensitive detection of p-aminophenol in real samples},
journal = {Microchimica Acta},
year = {2024},
doi = {10.1007/s00604-024-06204-8}
}
EUVIMED