Self-calibrating dual-sensing electrochemical sensors for accurate detection of carbon dioxide in blood

Da Yang, Jia An, Wu Qiu, Yuhan Gao, Jiajing Zhang, Wencai Pan, Peng Zhao, Yufei Liu

Microchimica Acta · 2024-01 · 191 (1)

DOI: 10.1007/s00604-023-06101-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, online erschienen am 13.12.2023. Verfasst von Da Yang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Optoelectronic Technology & Systems (Chongqing University), Ministry of Education, Chongqing, 400044, China. Hauptthemen laut MEDLINE: Carbon Dioxide, Biosensing Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A paper-based electrochemical dual-function biosensor capable of determining pH and TCO2 was synthesized for the first time using an iridium oxide pH electrode and an all-solid-state ion electrode (ASIE). In the study, to obtain highly reliable results, the biosensor was equipped with a real-time pH correction function before TCO2 measurements. Compared to traditional liquid-filling carbon dioxide detection sensors, the utilization of ferrocene endows our novel sensor with abundant positive sites, and thus greatly improves its performance. Conversely, the introduction of MXene with conductivity close to that of metals reduces electrode resistance, which is beneficial for accelerating the electrochemical reaction of the sensor and reducing LOD. After optimization, the detection range of TCO2 is 0.095 nM-0.66 M, with a detection limit of as low as 0.023 nM. In addition, the sensor was used in real serum sample-spiked recovery experiments and comparison experiments with existing clinical blood gas analyzers, which confirmed the effectiveness of its clinical application. This study provides a method for the rational design of paper-based electrochemical biosensors and a new approach for the clinical detection of blood carbon dioxide.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Carbon DioxideBiosensing TechniquesElectrochemical TechniquesElectrodes

Stichwörter der Autor:innen

Differential pulse voltammetryIon electrodeIridium oxideMXenePaper-based biosensor

Substanzen

Carbon Dioxide

Autor:innen und Institutionen

  • Key Laboratory of Optoelectronic Technology & Systems (Chongqing University), Ministry of Education, Chongqing, 400044, China.
  • School of Microelectronics, Southern University of Science and Technology, Shenzhen, 518055, China. anjia_love@163.com.
  • School of Rehabilitation Sciences and Engineering, University of Health and Rehabilitation Sciences, Qingdao, 400015, China.
  • School of Microelectronics, Southern University of Science and Technology, Shenzhen, 518055, China.
  • Center for Intelligent Sensing Technology, College of Optoelectronic Engineering, Chongqing University, Chongqing, 400044, China.
  • Department of Medical Engineering, Xinqiao Hospital, 183 Xinqiao Main Street, Chongqing, 400037, China.

Zitieren

APA

Yang, D., An, J., Qiu, W., Gao, Y., Zhang, J., Pan, W., Zhao, P., & Liu, Y. (2024). Self-calibrating dual-sensing electrochemical sensors for accurate detection of carbon dioxide in blood. Microchimica Acta, 191(1). https://doi.org/10.1007/s00604-023-06101-6

Vancouver

Yang D, An J, Qiu W, Gao Y, Zhang J, Pan W, et al. Self-calibrating dual-sensing electrochemical sensors for accurate detection of carbon dioxide in blood. Microchimica Acta. 2024;191(1). doi:10.1007/s00604-023-06101-6

BibTeX
@article{Yang2024,
  author = {Yang, Da and An, Jia and Qiu, Wu and Gao, Yuhan and Zhang, Jiajing and Pan, Wencai and Zhao, Peng and Liu, Yufei},
  title = {Self-calibrating dual-sensing electrochemical sensors for accurate detection of carbon dioxide in blood},
  journal = {Microchimica Acta},
  year = {2024},
  volume = {191},
  number = {1},
  doi = {10.1007/s00604-023-06101-6}
}