EUVIMEDEUVIMED entdecken
Crossref

COF-300-AR@CRL as a two-in-one nanocatalyst for one-step chemiluminescent detection of diphenyl ether herbicide residues in vegetable and fruit samples

Yuyu Ma, Yinhuan Li

Microchimica Acta · 2023

DOI: 10.1007/s00604-023-06077-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microchimica Acta, 2023. Verfasst von Yuyu Ma und 1 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry, Xi'an Jiaotong University, Xi'an, 710049, China. Hauptthemen laut MEDLINE: Herbicides, Vegetables. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Natural Science Foundation of Shaanxi Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A sensitive and accurate chemiluminescence (CL) method was developed for one-step determination of diphenyl ether herbicides at trace level with nitrofen (2,4-dichlorophenyl-p-nitrophenyl ether) as a model analyte. Candida rugosa lipase (CRL) was immobilized on a nanocarrier of amine-linked covalent organic framework (named as COF-300-AR) through a self-assembly strategy. The formed nanocomposite of COF-300-AR@CRL owns dual enzymatic catalytic activities. It can directly catalyze luminol-dissolved oxygen reaction to produce an intense CL emission by virtue of oxidase mimic activity of COF-300-AR but also effectively decompose nitrofen to release phenolic compounds by the immobilized CRL. The released phenolic compounds own strong reducing capacity and in turn decrease the CL signal sharply. Under the optimal conditions, the decreased CL intensity presents a good linear response to nitrofen concentration in the 0.02-50.0 μM range. The limit of detection (LOD, 3sb/S) is 11 nM and the precision is 2.0% for replicate measurements of 50.0 nM nitrofen solution (n = 11). This method has the advantages of rapid analytical efficiency, good selectivity, satisfactory stability, and recyclability. Recovery experiments were conducted on spiked vegetable and fruit samples with the recoveries falling in the range 90.0-107.0%.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HerbicidesVegetablesFruitPhenyl EthersLipasePhenols2,4-DinitrophenolSaccharomycetales

Stichwörter der Autor:innen

Candida rugosa lipaseCascade reactionChemiluminescenceCovalent organic frameworksNanozymeNitrofen

Substanzen

HerbicidesPhenyl EthersLipasePhenolsnitrofenphenyl ethernitrophen2,4-Dinitrophenol

Autor:innen und Institutionen

  • School of Chemistry, Xi'an Jiaotong University, Xi'an, 710049, China.
  • School of Chemistry, Xi'an Jiaotong University, Xi'an, 710049, China. liyh@mail.xjtu.edu.cn.

Förderung

  • Natural Science Foundation of Shaanxi Province

Zitieren

APA

Ma, Y., & Li, Y. (2023). COF-300-AR@CRL as a two-in-one nanocatalyst for one-step chemiluminescent detection of diphenyl ether herbicide residues in vegetable and fruit samples. Microchimica Acta. https://doi.org/10.1007/s00604-023-06077-3

Vancouver

Ma Y, Li Y. COF-300-AR@CRL as a two-in-one nanocatalyst for one-step chemiluminescent detection of diphenyl ether herbicide residues in vegetable and fruit samples. Microchimica Acta. 2023. doi:10.1007/s00604-023-06077-3

BibTeX
@article{Ma2023,
  author = {Ma, Yuyu and Li, Yinhuan},
  title = {COF-300-AR@CRL as a two-in-one nanocatalyst for one-step chemiluminescent detection of diphenyl ether herbicide residues in vegetable and fruit samples},
  journal = {Microchimica Acta},
  year = {2023},
  doi = {10.1007/s00604-023-06077-3}
}
Kostenlos starten →