Smartphone-integrated ratiometric fluorescence sensing platform based on bimetallic metal–organic framework nanowires for anthrax biomarker detection
Microchimica Acta · 2023
DOI: 10.1007/s00604-023-06065-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microchimica Acta, 2023. Verfasst von Ting Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Pharmacy, Chongqing Medical University, Chongqing, 400016, China. Hauptthemen laut MEDLINE: Anthrax, Metal-Organic Frameworks, Nanowires. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Chongqing, Youth Project of Science and Technology Research Program of Chongqing Education Commission of China.
Abstract (Originalsprache)
Developing an intelligent, sensitive, and visual strategy for quickly identifying anthrax biomarkers is crucial for ensuring food safety and preventing disease outbreaks. Herein, a smartphone-integrated ratiometric fluorescent sensing platform based on bimetallic metal-organic framework (Eux/Tb1-x-MOF) nanowires was designed for specific recognition of pyridine-2,6-dicarboxylic acid (DPA, anthrax biomarker). The Eux/Tb1-x-MOF was prepared by coordinating Eu3+ and Tb3+ with BBDC ligands, which exhibited a uniform fibrous morphology and dual-emission fluorescence at 543 and 614 nm. After the introduction of DPA, the red emission at 614 nm displayed obvious fluorescence quenching, while the green emission at 543 nm was gradually enhanced. The ratiometric sensing offered a wide linear equation in the range of 0.06-15 µg/mL and a low detection limit (LOD) of 20.69 ng/mL. Furthermore, a portable smartphone installing the color recognition application can achieve sensitive, real-time, and visual detection of DPA. As a simple and effective smartphone-assisted sensing platform, this work holds admirable promise to broaden the applications in biomarker real-time determinations and other fields.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- College of Pharmacy, Chongqing Medical University, Chongqing, 400016, China.
- Department of Pharmacy, The First Affiliated Hospital of Chongqing Medical and Pharmaceutical College, Chongqing, 400060, China.
- Department of Forensic Medicine, School of Basic Medical Sciences, Chongqing Medical University, Chongqing, 400016, China.
- College of Pharmacy, Chongqing Medical University, Chongqing, 400016, China. zzwcpu@cqmu.edu.cn.
- Department of Forensic Medicine, School of Basic Medical Sciences, Chongqing Medical University, Chongqing, 400016, China. lsqzzw@cqmu.edu.cn.
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Chongqing
- Youth Project of Science and Technology Research Program of Chongqing Education Commission of China
- CQMU Program for Youth Innovation in Future Medicine
Zitieren
APA
Wang, T., Zhang, J., Wu, Y., Wang, S., Jiang, X., Zhang, Z., & Li, S. (2023). Smartphone-integrated ratiometric fluorescence sensing platform based on bimetallic metal–organic framework nanowires for anthrax biomarker detection. Microchimica Acta. https://doi.org/10.1007/s00604-023-06065-7
Vancouver
Wang T, Zhang J, Wu Y, Wang S, Jiang X, Zhang Z, et al. Smartphone-integrated ratiometric fluorescence sensing platform based on bimetallic metal–organic framework nanowires for anthrax biomarker detection. Microchimica Acta. 2023. doi:10.1007/s00604-023-06065-7
BibTeX
@article{Wang2023,
author = {Wang, Ting and Zhang, Jieyuan and Wu, Yue and Wang, Shiyi and Jiang, Xinhui and Zhang, Zhengwei and Li, Siqiao},
title = {Smartphone-integrated ratiometric fluorescence sensing platform based on bimetallic metal–organic framework nanowires for anthrax biomarker detection},
journal = {Microchimica Acta},
year = {2023},
doi = {10.1007/s00604-023-06065-7}
}
EUVIMED