Impact of surgeon qualifications on the safety of Robot-Assisted surgery
Surgery Today · 2026-07 · 56 (7) · 1395-1400
DOI: 10.1007/s00595-026-03252-w ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Surgery Today, online erschienen am 09.02.2026. Verfasst von Tetsuro Tominaga und 17 weiteren Autor:innen. Beteiligte Einrichtung: Division of Surgical Oncology, Department of Surgery, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501,…. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Surgeons, Clinical Competence, Colorectal Neoplasms. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To evaluate how surgeons' experience and qualifications in laparoscopic surgery influence safe implementation of robotic surgery. METHODS: We retrospectively reviewed 652 patients with colorectal cancer who underwent robotic surgery between 2016 and 2024 years. The patients were divided into two groups: those who underwent surgery performed by an expert surgeon (expert group, n = 571) and a non-expert surgeon (non-expert group, n = 81). Following propensity score matching (PSM) to minimize the possibility of any selection bias, 81 patients in each group were matched, and the clinical and perioperative features were compared between the two groups. RESULTS: The number of procedures performed by non-experts has gradually increased over time, and surgeons have become progressively younger. Before matching, the non-expert group had a higher American Society of Anesthesiologists physical status (expert vs. non-expert: 13.6% vs. 4.6%, p < 0.001) and included a higher proportion of colon tumors (36.4% vs. 54.3%, p = 0.002). However, after matching, no differences were observed between the groups. Furthermore, there were no significant differences in the operative time, blood loss, or postoperative complications. CONCLUSIONS: Proctored robotic surgery is considered to be safe. However, when non-expert surgeons perform robotic surgery, expert supervision is desirable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Surgical Oncology, Department of Surgery, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
- Colorectal Surgery, Department of Surgery, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
- Department of Surgery, Sasebo City General Hospital, 9-3 Hirasemachi, Nagasaki, 857-8511, Japan.
- Department of Surgery, National Hospital Organization Nagasaki Medical Center, 1-1001-1, Omura, Nagasaki, 856-8562, Japan.
- Department of Surgery, Isahaya General Hospital, 24-1, Isahaya, Nagasaki, 854-8501, Japan.
- Department of Surgery, Ureshino Medical Center, Ureshino, 4279-3, 843-0393, Saga, Japan.
Zitieren
APA
Tominaga, T., Noda, K., Takamura, Y., Katayama, H., Hashimoto, S., Yamashita, M., Tei, S., Ono, R., Ishii, M., Hisanaga, M., Oishi, K., Moriyama, M., Uchida, F., Shiraishi, T., Kunizaki, M., Fukuda, A., Nonaka, T., & Matsumoto, K. (2026). Impact of surgeon qualifications on the safety of Robot-Assisted surgery. Surgery Today, 56(7), 1395-1400. https://doi.org/10.1007/s00595-026-03252-w
Vancouver
Tominaga T, Noda K, Takamura Y, Katayama H, Hashimoto S, Yamashita M, et al. Impact of surgeon qualifications on the safety of Robot-Assisted surgery. Surgery Today. 2026;56(7):1395-1400. doi:10.1007/s00595-026-03252-w
BibTeX
@article{Tominaga2026,
author = {Tominaga, Tetsuro and Noda, Keisuke and Takamura, Yuma and Katayama, Hiroki and Hashimoto, Shintaro and Yamashita, Mariko and Tei, Shoko and Ono, Rika and Ishii, Mitsutoshi and Hisanaga, Makoto and Oishi, Kaido and Moriyama, Masaaki and Uchida, Fumitake and Shiraishi, Toshio and Kunizaki, Masaki and Fukuda, Akiko and Nonaka, Takashi and Matsumoto, Keitaro},
title = {Impact of surgeon qualifications on the safety of Robot-Assisted surgery},
journal = {Surgery Today},
year = {2026},
volume = {56},
number = {7},
pages = {1395--1400},
doi = {10.1007/s00595-026-03252-w}
}
EUVIMED