Impact of data compression and security devices on telesurgery systems
Surgery Today · 2026
DOI: 10.1007/s00595-025-03142-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Surgery Today, 2026. Verfasst von Hajime Morohashi und 9 weiteren Autor:innen. Beteiligte Einrichtung: Committee for Promotion of Remote Surgery Implementation, Japan Surgical Society, Tokyo, Japan. hm2002@hirosaki-u.ac.jp. Hauptthemen laut MEDLINE: Computer Security, Data Compression, Telemedicine, Robotic Surgical Procedures. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Agency for Medical Research and Development (AMED).
Abstract (Originalsprache)
Purpose
To evaluate the feasibility of secure telesurgery by assessing the impact of image compression and cybersecurity devices on surgical performance and data transmission.
Methods
Telesurgical procedures using the hinotori™ surgical robot were performed remotely between Hirosaki and Goshogawara, which are 30 km apart, over a secure line provided by NTT East. Image compression was tested at 120, 80, 60, 40, and 20 Mbps. A surgical specialist operated on artificial organ models. Simulated cyberattacks were introduced to assess the performance of security devices.
Results
Even at 20 Mbps, there was no significant loss in operability or image quality. Security devices detected simulated attacks and permitted essential robot communications. No visual distortion or operational issues occurred, and only a small delay of ≤ 2 min was introduced. The transmission control protocol (TCP) error rates remained low, with or without security devices (0.00–0.04%).
Conclusion
Security implementation enables safe telesurgery by detecting cyber threats without impairing surgical performance. This finding supports the practical development of economically and technologically viable telesurgical systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Committee for Promotion of Remote Surgery Implementation, Japan Surgical Society, Tokyo, Japan. hm2002@hirosaki-u.ac.jp.
- Department of Gastroenterological Surgery, Hirosaki University Graduate School of Medicine, 5 Zaifu-cho, Hirosaki-shi, Aomori, 036-8562, Japan. hm2002@hirosaki-u.ac.jp.
- Committee for Promotion of Remote Surgery Implementation, Japan Surgical Society, Tokyo, Japan.
- Department of Gastroenterological Surgery, Hirosaki University Graduate School of Medicine, 5 Zaifu-cho, Hirosaki-shi, Aomori, 036-8562, Japan.
- Department of Gastroenterological Surgery II, Faculty of Medicine, Graduate School of Medicine, Hokkaido University, Sapporo, Japan.
- Center for Integration of Advanced Medicine, Life Science and Innovative Technology (CAMIT), Kyushu University Hospital, Fukuoka, Japan.
Förderung
- Japan Agency for Medical Research and Development (AMED)
Zitieren
APA
Morohashi, H., Hakamada, K., Wakasa, Y., Yokoyama, K., Ebihara, Y., Hirano, S., Oki, E., Ikeda, N., Taketomi, A., & Mori, M. (2026). Impact of data compression and security devices on telesurgery systems. Surgery Today. https://doi.org/10.1007/s00595-025-03142-7
Vancouver
Morohashi H, Hakamada K, Wakasa Y, Yokoyama K, Ebihara Y, Hirano S, et al. Impact of data compression and security devices on telesurgery systems. Surgery Today. 2026. doi:10.1007/s00595-025-03142-7
BibTeX
@article{Morohashi2026,
author = {Morohashi, Hajime and Hakamada, Kenichi and Wakasa, Yusuke and Yokoyama, Kazuki and Ebihara, Yuma and Hirano, Satoshi and Oki, Eiji and Ikeda, Norihiko and Taketomi, Akinobu and Mori, Masaki},
title = {Impact of data compression and security devices on telesurgery systems},
journal = {Surgery Today},
year = {2026},
doi = {10.1007/s00595-025-03142-7}
}
EUVIMED