A graft-to-recipient weight ratio of less than 0.7% under portal venous hemodynamics monitoring is a risk factor for early graft loss after living donor liver transplantation
Surgery Today · 2025
DOI: 10.1007/s00595-025-03103-0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Surgery Today, 2025. Verfasst von Niang-Cheng Lin und 11 weiteren Autor:innen. Beteiligte Einrichtung: Division of Transplantation Surgery, Department of Surgery, Taipei Veterans General Hospital, No. 201, Section 2, Shih-Pai Road, Taipei, 11217, Taiwa…. Hauptthemen laut MEDLINE: Liver Transplantation, Living Donors, Portal Vein, Hemodynamics. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To investigate the interaction between graft-to-recipient weight ratio (GRWR) and portal venous hemodynamics (PVH), with a net impact on the perioperative outcomes of living donor liver transplantation (LDLT). METHODS: We analyzed, retrospectively, adult LDLT recipients divided into three groups according to their GRWR: Group 1, > 1.0% (n = 124); Group 2, 0.8 ~ 1.0% (n = 70); and Group 3, 0.8%. Patients with extremely small liver grafts had significantly lower graft survival rates (1-month, 3-months, and 1-year post-LDLT, of 66.7%, 50.0%, and 50.0%, respectively (p < 0.01). CONCLUSION: Under intraoperative PVH monitoring, the accepted GRWR in LDLT could be extended to 0.7%, but a GRWR < 0.7% remains a risk factor for early graft loss.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Transplantation Surgery, Department of Surgery, Taipei Veterans General Hospital, No. 201, Section 2, Shih-Pai Road, Taipei, 11217, Taiwan, ROC.
- School of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan, ROC.
- Division of General Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan, ROC.
- Division of Pediatric Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan, ROC.
- Department of Anesthesiology, Taipei Veterans General Hospital, Taipei, Taiwan, ROC.
- Division of Transplantation Surgery, Department of Surgery, Taipei Veterans General Hospital, No. 201, Section 2, Shih-Pai Road, Taipei, 11217, Taiwan, ROC. csliu@vghtpe.gov.tw.
Zitieren
APA
Lin, N. C., Chen, C. Y., Lei, H. J., Tsai, H. L., Tsou, Y. F., Kuo, F. C., Chung, M. H., Hsia, C. Y., Loong, C. C., Chou, S. C., Wang, S. C., & Liu, C. (2025). A graft-to-recipient weight ratio of less than 0.7% under portal venous hemodynamics monitoring is a risk factor for early graft loss after living donor liver transplantation. Surgery Today. https://doi.org/10.1007/s00595-025-03103-0
Vancouver
Lin NC, Chen CY, Lei HJ, Tsai HL, Tsou YF, Kuo FC, et al. A graft-to-recipient weight ratio of less than 0.7% under portal venous hemodynamics monitoring is a risk factor for early graft loss after living donor liver transplantation. Surgery Today. 2025. doi:10.1007/s00595-025-03103-0
BibTeX
@article{Lin2025,
author = {Lin, Niang-Cheng and Chen, Cheng-Yen and Lei, Hao-Jan and Tsai, Hsin-Lin and Tsou, Yi-Fan and Kuo, Fang-Cheng and Chung, Meng-Hsuan and Hsia, Cheng-Yuan and Loong, Che-Chuan and Chou, Shu-Cheng and Wang, Shen-Chih and Liu, Chinsu},
title = {A graft-to-recipient weight ratio of less than 0.7% under portal venous hemodynamics monitoring is a risk factor for early graft loss after living donor liver transplantation},
journal = {Surgery Today},
year = {2025},
doi = {10.1007/s00595-025-03103-0}
}
EUVIMED