EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Safety and efficacy of new staple-line reinforcement in lung resection: a prospective study of 48 patients

Suguru Mitsui, Yugo Tanaka, Megumi Nishikubo, Takefumi Doi, Shinya Tane, Daisuke Hokka, Yuji Mitomo, Yoshimasa Maniwa

Surgery Today · 2024

DOI: 10.1007/s00595-024-02798-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Surgery Today, 2024. Verfasst von Suguru Mitsui und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Thoracic Surgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuou-ku, Kobe, Hyogo, 650-0017, Japan. Hauptthemen laut MEDLINE: Pneumonectomy, Surgical Stapling, Postoperative Complications, Length of Stay. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Kobe University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the safety and efficacy of new staple-line reinforcement (SLR) in pulmonary resection through a prospective study and to compare the results of this study with historical control data in an exploratory study.

Methods

The subjects of this study were 48 patients who underwent thoracoscopic lobectomy. The primary endpoint was air leakage from the staple line. The secondary endpoints were the location of air leakage, duration of air leakage, and postoperative pulmonary complications.

Results

The incidence of intraoperative air leakage from the staple line was 6.3%. Three patients had prolonged air leakage as a postoperative pulmonary complication. No malfunction was found in patients who underwent SLR with the stapling device. When compared with the historical group, the SLR group had a significantly lower incidence of air leakage from the staple line (6.3% vs. 28.5%, P < 0.001) and significantly shorter indwelling chest drainage time ( P = 0.049) and length of hospital stay ( P < 0.001).

Conclusions

The use of SLR in pulmonary resection was safe and effective. When compared with conventional products, SLR could control intraoperative air leakage from the staple line and shorten time needed for indwelling chest drainage and the length of hospital stay.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PneumonectomySurgical StaplingPostoperative ComplicationsLength of StayHumansProspective StudiesFemaleMaleAgedMiddle AgedTreatment OutcomeThoracoscopyIntraoperative ComplicationsAdultIncidenceSafetyTime Factors

Stichwörter der Autor:innen

Air leakageAutomated suturing deviceBioabsorbable staple-line reinforcementPulmonary resection

Autor:innen und Institutionen

  • Division of Thoracic Surgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuou-ku, Kobe, Hyogo, 650-0017, Japan.
  • Division of Thoracic Surgery, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuou-ku, Kobe, Hyogo, 650-0017, Japan. tanakay@med.kobe-u.ac.jp.
  • Clinical and Translational Research Center, Kobe University Hospital, Kobe, Hyogo, Japan.

Förderung

  • Kobe University

Zitieren

APA

Mitsui, S., Tanaka, Y., Nishikubo, M., Doi, T., Tane, S., Hokka, D., Mitomo, Y., & Maniwa, Y. (2024). Safety and efficacy of new staple-line reinforcement in lung resection: a prospective study of 48 patients. Surgery Today. https://doi.org/10.1007/s00595-024-02798-x

Vancouver

Mitsui S, Tanaka Y, Nishikubo M, Doi T, Tane S, Hokka D, et al. Safety and efficacy of new staple-line reinforcement in lung resection: a prospective study of 48 patients. Surgery Today. 2024. doi:10.1007/s00595-024-02798-x

BibTeX
@article{Mitsui2024,
  author = {Mitsui, Suguru and Tanaka, Yugo and Nishikubo, Megumi and Doi, Takefumi and Tane, Shinya and Hokka, Daisuke and Mitomo, Yuji and Maniwa, Yoshimasa},
  title = {Safety and efficacy of new staple-line reinforcement in lung resection: a prospective study of 48 patients},
  journal = {Surgery Today},
  year = {2024},
  doi = {10.1007/s00595-024-02798-x}
}
Kostenlos starten →