Wearable sensor-derived continuous physical activity dimensions and all-cause mortality in adults with diabetes and hypertension: insights from two population-based accelerometry cohorts
Acta Diabetologica · 06.08.2026 · 63 (11) · 1887-1896
DOI: 10.1007/s00592-026-02768-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Diabetologica, online erschienen am 06.08.2026. Verfasst von Tianchen Niu und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Computer Science, Sichuan University, Chengdu, China. Hauptthemen laut MEDLINE: Hypertension, Accelerometry, Diabetes Mellitus, Exercise. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: Key Technologies Research and Development Program of Anhui Province, National Science and Technology Innovation 2030, Noncommunicable Chronic Diseases-National Science and Technology Major Project, Science and Technology Department of Sichuan Province.
Themen: Diabetes mellitus
Abstract (Originalsprache)
AIMS/INTRODUCTION: Adults with coexistent diabetes mellitus and hypertension (DM-HTN) have a substantially elevated risk of all-cause mortality. Physical activity (PA) is a key modifiable factor, yet conventional self-reported or categorical measures may fail to capture clinically relevant variation. We investigated associations between sensor-derived continuous PA dimensions and all-cause mortality in DM-HTN. MATERIALS AND METHODS: We analysed 4,294 DM-HTN and 1,482 diabetes-alone adults from the UK Biobank (median follow-up 85.2 months; 731 deaths) and 530 DM-HTN and 235 diabetes-alone participants from NHANES 2011-2014 (mean follow-up 63.5 months; 123 deaths), all with device-measured wrist accelerometry. Continuous sensor-derived metrics included Daily MET/MIMS (volume) and Peak-30 MET/MIMS (peak intensity). Associations with all-cause mortality were examined using multivariable Cox regression, restricted cubic spline modelling, and GBDT models with SHAP attribution. RESULTS: Both continuous PA dimensions were independently associated with all-cause mortality in the DM-HTN group across cohorts. In the UK Biobank, fully adjusted hazard ratios were 0.66 for Daily MET and 0.43 for Peak-30 MET. In NHANES, Peak-30 MIMS showed robust associations (HR = 0.57, p < 0.001), while Daily MIMS attenuated to non-significance (HR = 0.95, p = 0.116) after full adjustment. Non-linear dose-response modelling identified lower inflection points for peak intensity in DM-HTN compared with diabetes-alone individuals. SHAP analyses confirmed that continuous peak intensity maintained stable protective contributions across comorbidity strata. CONCLUSIONS: Wearable sensor-derived continuous PA dimensions capture mortality risk gradients in DM-HTN that are inaccessible to conventional approaches. Population-specific, clinically attainable inflection thresholds identified through continuous monitoring support incorporating sensor-derived PA metrics as digital biomarkers in comorbidity-specific risk stratification frameworks.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Computer Science, Sichuan University, Chengdu, China.
- Department of Rehabilitation Medicine, West China Hospital, Chengdu, China.
- Center of Gerontology and Geriatrics, West China Hospital, Sichuan University, Chengdu, China.
- Department of Pediatrics, Section of Biomedical Informatics, University of Chicago, Chicago, IL, USA. junhanzv@uchicago.edu.
- Department of Biomedical Informatics, Harvard Medical School, Boston, MA, USA. junhanzv@uchicago.edu.
- College of Computer Science, Sichuan University, Chengdu, China. lintao@scu.edu.cn.
Förderung
- Key Technologies Research and Development Program of Anhui Province
- National Science and Technology Innovation 2030, Noncommunicable Chronic Diseases-National Science and Technology Major Project
- Science and Technology Department of Sichuan Province
Zitieren
APA
Niu, T., Fan, L., Lian, R., Wang, F., Zhao, J., & Lin, T. (2026). Wearable sensor-derived continuous physical activity dimensions and all-cause mortality in adults with diabetes and hypertension: insights from two population-based accelerometry cohorts. Acta Diabetologica, 63(11), 1887-1896. https://doi.org/10.1007/s00592-026-02768-4
Vancouver
Niu T, Fan L, Lian R, Wang F, Zhao J, Lin T. Wearable sensor-derived continuous physical activity dimensions and all-cause mortality in adults with diabetes and hypertension: insights from two population-based accelerometry cohorts. Acta Diabetologica. 2026;63(11):1887-1896. doi:10.1007/s00592-026-02768-4
BibTeX
@article{Niu2026,
author = {Niu, Tianchen and Fan, Lingjie and Lian, Rongna and Wang, Fengyi and Zhao, Junhan and Lin, Tao},
title = {Wearable sensor-derived continuous physical activity dimensions and all-cause mortality in adults with diabetes and hypertension: insights from two population-based accelerometry cohorts},
journal = {Acta Diabetologica},
year = {2026},
volume = {63},
number = {11},
pages = {1887--1896},
doi = {10.1007/s00592-026-02768-4}
}
EUVIMED