Pregnancy outcomes with the pregestational use of Minimed 780G compared to Minimed 640G: findings from a multicenter cohort study
Acta Diabetologica · 2024
DOI: 10.1007/s00592-024-02430-x ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Acta Diabetologica, 2024. Verfasst von Verónica Perea und 19 weiteren Autor:innen. Beteiligte Einrichtung: Hospital Universitari Mútua de Terrassa, 5 Doctor Robert Sq, 08221, Terrassa, Spain. vperea@mutuaterrassa.cat. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 1, Pregnancy in Diabetics, Insulin, Hypoglycemic Agents. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 46 Literaturangaben.
Abstract (Originalsprache)
AIM: To compare glycemic control and maternal-fetal outcomes of women with type 1 diabetes (T1D) using Minimed™ 780G (MM780G) with those women using Minimed™ 640G (MM640G) since before pregnancy. METHODS: Multicenter prospective cohort study of pregnant women with T1D in Spain. We evaluated HbA1c, time spent within (TIRp), below (TBRp) and above (TARp) the pregnancy-specific glucose range 3.5-7.8 mmol/L (63-140 mg/dL) and glucose variability (CV). RESULTS: Sixty-nine women were included (MM780G n = 40). At baseline, MM640G users had higher rates of severe hypoglycemia before pregnancy, without other between-group differences. The MM780G group had higher TIRp and lower TARp, TBRp and CV, but similar HbA1c in the first trimester of gestation. TBRp and CV remained significantly higher in the MM640G group throughout pregnancy. Higher HbA1c was observed in the MM780G group compared to the MM640G (6.28 ± 0.53% [45.1 ± 5.8 mmol/mol] vs. 5.97 ± 0.62 [41.8 ± 6.8], p = 0.003) in the second trimester. There were no differences in the mean change in HbA1c from the first to the third trimester of gestation between groups. MM780G users were more likely to have large-for-gestational-age infants (ORadjusted 4.85, 95% CI 1.46-16.13, p = 0.010), macrosomia (ORadjusted 12.17, 95% CI 1.49-99.72, p = 0.020) and cesarean section (ORadjusted 4.19, 95% CI 1.34-13.11, p = 0.014) than the MM640G group. CONCLUSIONS: Pregestational use of MM780G led to an initial improvement in TIRp, but this was not sustained in the second and third trimesters, with a 4-fold increased risk of delivering a LGA infant and undergoing cesarean section compared to MM640G users.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Hospital Universitari Mútua de Terrassa, 5 Doctor Robert Sq, 08221, Terrassa, Spain. vperea@mutuaterrassa.cat.
- Hospital Universitari Mútua de Terrassa, 5 Doctor Robert Sq, 08221, Terrassa, Spain.
- Hospital Universitario Nuestra Señora de la Candelaria, Santa Cruz de Tenerife, Spain.
- Hospital Infanta Sofía, Madrid, Spain.
- Complejo Hospitalario Universitario Insular Materno-Infantil de Canarias, Universidad de las Palmas de Gran Canaria, Gran Canaria, Spain.
- Hospital Universitario de Badajoz, Badajoz, Spain.
Zitieren
APA
Perea, V., Quirós, C., Herrera-Arranz, M. T., Azriel-Mira, S., Wägner, A. M., Beato-Vibora, P., Soldevila, B., Barquiel, B., Pardo, R. M., Díaz-Soto, G., Picón, M. J., Colomo, N., Amigó, J., Climent, E., Durán-Martínez, M., Corcoy, R., Codina, M., Cuesta, M., Guedes, B. V., & Vinagre, I. (2024). Pregnancy outcomes with the pregestational use of Minimed 780G compared to Minimed 640G: findings from a multicenter cohort study. Acta Diabetologica. https://doi.org/10.1007/s00592-024-02430-x
Vancouver
Perea V, Quirós C, Herrera-Arranz MT, Azriel-Mira S, Wägner AM, Beato-Vibora P, et al. Pregnancy outcomes with the pregestational use of Minimed 780G compared to Minimed 640G: findings from a multicenter cohort study. Acta Diabetologica. 2024. doi:10.1007/s00592-024-02430-x
BibTeX
@article{Perea2024,
author = {Perea, Verónica and Quirós, Carmen and Herrera-Arranz, María Teresa and Azriel-Mira, Sharona and Wägner, Ana M and Beato-Vibora, Pilar and Soldevila, Berta and Barquiel, Beatriz and Pardo, Rosa Márquez and Díaz-Soto, Gonzalo and Picón, Maria José and Colomo, Natalia and Amigó, Judit and Climent, Elisenda and Durán-Martínez, María and Corcoy, Rosa and Codina, Mercedes and Cuesta, Martín and Guedes, Begoña Vega and Vinagre, Irene},