EUVIMEDEUVIMED entdecken
Crossref

Mid-term clinical and radiographic outcomes at minimum five-year follow-up after stemless reverse shoulder arthroplasty

Stephanie Geyer, Cedric Oettle, Larissa Eckl, Christian Schoch

European Journal of Orthopaedic Surgery & Traumatology · 08.08.2026 · 36 (1)

DOI: 10.1007/s00590-026-04880-1 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, online erschienen am 08.08.2026. Verfasst von Stephanie Geyer und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department for Shoulder and Elbow Surgery, St. Vinzenz Kliniken Pfronten im Allgäu, Pfronten, Germany. steffigeyer@gmx.net. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Shoulder Prosthesis, Shoulder Joint. Die Arbeit nennt 20 Literaturangaben. Gefördert von: Enovis.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Stemless reverse total shoulder arthroplasty (rTSA) was developed to preserve humeral bone stock and facilitate revision surgery. While short-term outcomes are promising, mid-term data beyond five years remain limited. The purpose of this study was to evaluate clinical and radiographic outcomes at a minimum follow-up of five years after implantation of a stemless reverse shoulder prosthesis. We hypothesized that metaphyseal fixation would demonstrate sustained clinical function and stable radiographic integration at mid-term follow-up. METHODS: This retrospective case series included 44 consecutive patients who underwent stemless rTSA. At minimum five-year follow-up, 35 patients were available for clinical and radiographic evaluation (follow-up rate 79.5%). Clinical assessment included the Constant Score (CS), age-adjusted Constant Score, American Shoulder and Elbow Surgeons (ASES) score, Simple Shoulder Test (SST), and Visual Analog Scale (VAS) for pain. Radiographic evaluation was performed using standardized two-plane radiographs and assessed for humeral and glenoid radiolucency, implant subsidence, loosening, and scapular notching. RESULTS: At a median follow-up of 69 months, patients demonstrated sustained functional outcomes with a median Constant Score of 74 (IQR 71-78), ASES score of 85 (IQR 80-95), SST score of 9.1 ± 2.0, and VAS pain score of 1 (IQR 0-2). The absolute Constant Score decreased slightly between the two- and five-year follow-up; however, this difference was not statistically significant (p = 0.264). Incomplete humeral radiolucent lines < 1 mm were observed in 3 patients (10.7%) and glenoid radiolucent lines in 2 patients (7.1%). No progressive loosening or implant migration was detected. CONCLUSION: Stemless reverse shoulder arthroplasty demonstrated favorable clinical outcomes and stable radiographic metaphyseal fixation at a minimum follow-up of five years. No progressive radiographic changes or implant-related complications were observed beyond the initial two postoperative years. While these findings support the mid-term performance of this implant concept, further studies with larger patient cohorts are warranted to confirm these results. LEVEL OF EVIDENCE: IV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, ShoulderShoulder ProsthesisShoulder JointHumansRetrospective StudiesFollow-Up StudiesFemaleAgedRadiographyMaleTreatment OutcomeMiddle AgedReoperationRange of Motion, ArticularProsthesis DesignProsthesis Failure

Stichwörter der Autor:innen

Bone preservationFunctional outcomeMidterm follow upRadiographic analysisStemless reverse shoulder arthroplasty

Autor:innen und Institutionen

  • Department for Shoulder and Elbow Surgery, St. Vinzenz Kliniken Pfronten im Allgäu, Pfronten, Germany. steffigeyer@gmx.net.
  • Department for Shoulder and Elbow Surgery, St. Vinzenz Kliniken Pfronten im Allgäu, Pfronten, Germany.
  • Department of Sports Orthopedics, Rechts der Isar Hospital, Munich, Germany.

Förderung

  • Enovis

Zitieren

APA

Geyer, S., Oettle, C., Eckl, L., & Schoch, C. (2026). Mid-term clinical and radiographic outcomes at minimum five-year follow-up after stemless reverse shoulder arthroplasty. European Journal of Orthopaedic Surgery & Traumatology, 36(1). https://doi.org/10.1007/s00590-026-04880-1

Vancouver

Geyer S, Oettle C, Eckl L, Schoch C. Mid-term clinical and radiographic outcomes at minimum five-year follow-up after stemless reverse shoulder arthroplasty. European Journal of Orthopaedic Surgery & Traumatology. 2026;36(1). doi:10.1007/s00590-026-04880-1

BibTeX
@article{Geyer2026,
  author = {Geyer, Stephanie and Oettle, Cedric and Eckl, Larissa and Schoch, Christian},
  title = {Mid-term clinical and radiographic outcomes at minimum five-year follow-up after stemless reverse shoulder arthroplasty},
  journal = {European Journal of Orthopaedic Surgery & Traumatology},
  year = {2026},
  volume = {36},
  number = {1},
  doi = {10.1007/s00590-026-04880-1}
}
Kostenlos starten →