Medium- to long-term results of press-fit radial head arthroplasty in acute fractures and post-traumatic conditions
European Journal of Orthopaedic Surgery & Traumatology · 29.06.2026 · 36 (1)
DOI: 10.1007/s00590-026-04850-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, online erschienen am 29.06.2026. Verfasst von Giuseppe Giannicola und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anatomic, Histological, Forensic Medicine and Orthopedic sciences, Sapienza University of Rome, Rome, Italy. Hauptthemen laut MEDLINE: Elbow Joint, Radius Fractures, Elbow Prosthesis, Radial Head and Neck Fractures. Die Arbeit nennt 28 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: The aim of this study was to assess the clinical results and the causes of implant failure of press-fit radial head arthroplasty (RHA) in the medium- to long-term. METHODS: 97 consecutive patients treated with a press-fit RHA by a single surgeon were analyzed. According to the type of implant they received there were 56 patients with a bipolar prosthesis and 41 patients with an anatomical prosthesis. At the last follow-up, the patients underwent X-rays and clinical evaluation based on the Mayo Elbow Performance Score (MEPS), the patient-assessed American Shoulder and Elbow Surgeons score-Elbow (p-ASES-E), and the Disabilities of the Arm, Shoulder and Hand questionnaire (QuickDASH). The causes of reintervention and implant failure were recorded. RESULTS: The mean follow-up was 9 years (5-17 years); 24 patients were followed up for longer than 12 years. At the last follow-up, the average flexion, extension, pronation and supination were 139°, 15.2°, 82° and 81.2° in the whole cohort of patients, respectively. The MEPS, QuickDASH and p-ASES-e were 94.3, 6.7 and 93.6, respectively. Four patients underwent reinterventions due to 3 bipolar implant disassembly caused by new traumas and 1 aseptic loosening of an anatomical RHA. CONCLUSIONS: Both press-fit radial head arthroplasty implants analyzed yielded satisfactory clinical and radiographic results in the medium to long-term in most patients, with a very low incidence of implant-related reinterventions (4.1%). In the absence of a pre-specified non-inferiority framework, no formal equivalence claim between the two implant designs can be made on the basis of the present study. LEVEL OF EVIDENCE: IV.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anatomic, Histological, Forensic Medicine and Orthopedic sciences, Sapienza University of Rome, Rome, Italy.
- Department of Orthopedics and Traumatology, Azienda Ospedaliera San Camillo-Forlanini, Rome, Italy. p.sessa@hotmail.it.
ORCID-Profile: Pasquale Sessa
Zitieren
APA
Giannicola, G., Amura, A., Prigent, S., Fabbri, M., & Sessa, P. (2026). Medium- to long-term results of press-fit radial head arthroplasty in acute fractures and post-traumatic conditions. European Journal of Orthopaedic Surgery & Traumatology, 36(1). https://doi.org/10.1007/s00590-026-04850-7
Vancouver
Giannicola G, Amura A, Prigent S, Fabbri M, Sessa P. Medium- to long-term results of press-fit radial head arthroplasty in acute fractures and post-traumatic conditions. European Journal of Orthopaedic Surgery & Traumatology. 2026;36(1). doi:10.1007/s00590-026-04850-7
BibTeX
@article{Giannicola2026,
author = {Giannicola, Giuseppe and Amura, Andrea and Prigent, Sebastien and Fabbri, Mattia and Sessa, Pasquale},
title = {Medium- to long-term results of press-fit radial head arthroplasty in acute fractures and post-traumatic conditions},
journal = {European Journal of Orthopaedic Surgery & Traumatology},
year = {2026},
volume = {36},
number = {1},
doi = {10.1007/s00590-026-04850-7}
}
EUVIMED