EUVIMEDEUVIMED entdecken
LeitlinieOpen Access · CC BY 4.0

Development of intraoperative fluoroscopic protocols to avoid rotational malalignment during nailing of femoral fractures: a step-by-step guideline using the lesser trochanter profile or true lateral view

Daniel J Vermue, Pim J Bongers, Kaj Ten Duis, Job N Doornberg, Ruurd L Jaarsma, Mostafa El Moumni, Nils Jan Bleeker, Raul G Plomp, Frank F A IJpma, 3D Surgery Consortium.

European Journal of Orthopaedic Surgery & Traumatology · 24.06.2026 · 36 (1)

DOI: 10.1007/s00590-026-04810-1 ↗

Kurz gefasst

Leitlinie in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, online erschienen am 24.06.2026. Verfasst von Daniel J Vermue und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Trauma Surgery, University Medical Center Groningen, Groningen, The Netherlands. d.j.vermue@umcg.nl. Hauptthemen laut MEDLINE: Femoral Fractures, Fracture Fixation, Intramedullary, Bone Malalignment, Femur. Die Arbeit nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Rotational malalignment (≥ 15°) occurs in up to 35% of femoral fractures after intramedullary nailing, and standardized fluoroscopy protocols to prevent malrotation are lacking. We developed and evaluated two easy-to-use intraoperative fluoroscopy techniques to reduce malrotation.

Methods

A human specimen study was performed to compare two standardized fluoroscopy protocols—the lesser trochanter profile and the true lateral view—with current clinical practice. A mid-shaft femoral fracture was created in a full-body cadaver, and an unlocked intramedullary nail was inserted. Random degrees of rotational malalignment were applied using a goniometer and reference wires at the fracture site. Ten physicians (consultants and residents) first estimated malrotation and then performed 150 rotational corrections: 50 according to (unstandardized) clinical practice, 50 using the lesser trochanter profile, and 50 using the true lateral view. The primary outcome was rotational malalignment, measured using reference wires at the fracture site.

Results

Clinicians’ visual estimation deviated 15.5° [IQR 18.5–12.0] from actual malrotation. Corrections using unstandardized methods resulted in 12.5° [IQR 18.2–6.1] of malrotation. In contrast, the lesser trochanter and true lateral protocols reduced malrotation to 3.9° [6.8–2.1] and 3.6° [8.6–1.4], respectively. Both were significantly more accurate than current practice ( p = 0.009 and p = 0.017). Surgeons favoured the lesser trochanter profile for its efficiency, ease-to-use, and minimal need for C-arm repositioning.

Conclusion

This study introduces two step-by-step standardized fluoroscopy protocols to prevent rotational malalignment in femoral nailing. Both outperform traditional, unstandardized correction methods, with the lesser trochanter profile offering a more practical and time-efficient option for intraoperative use.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Femoral FracturesFracture Fixation, IntramedullaryBone MalalignmentFemurHumansFluoroscopyRotationCadaverBone NailsPractice Guidelines as Topic

Stichwörter der Autor:innen

FemurFluoroscopyFracturesLesser trochanterMalrotationTrue lateral technique

Autor:innen und Institutionen

  • Department of Trauma Surgery, University Medical Center Groningen, Groningen, The Netherlands. d.j.vermue@umcg.nl.
  • Department of Trauma Surgery, University Medical Center Groningen, Groningen, The Netherlands.
  • Orthopaedic Trauma Surgery, Flinders Medical Centre, Bedford Park, Australia.
  • Department of Orthopaedic Surgery, Amsterdam University Medical Centers, Amsterdam, The Netherlands.

Zitieren

APA

Vermue, D. J., Bongers, P. J., Ten Duis, K., Doornberg, J. N., Jaarsma, R. L., El Moumni, M., Bleeker, N. J., Plomp, R. G., IJpma, F. F. A., & 3D Surgery Consortium. (2026). Development of intraoperative fluoroscopic protocols to avoid rotational malalignment during nailing of femoral fractures: a step-by-step guideline using the lesser trochanter profile or true lateral view. European Journal of Orthopaedic Surgery & Traumatology, 36(1). https://doi.org/10.1007/s00590-026-04810-1

Vancouver

Vermue DJ, Bongers PJ, Ten Duis K, Doornberg JN, Jaarsma RL, El Moumni M, et al. Development of intraoperative fluoroscopic protocols to avoid rotational malalignment during nailing of femoral fractures: a step-by-step guideline using the lesser trochanter profile or true lateral view. European Journal of Orthopaedic Surgery & Traumatology. 2026;36(1). doi:10.1007/s00590-026-04810-1

BibTeX
@article{Vermue2026,
  author = {Vermue, Daniel J and Bongers, Pim J and Ten Duis, Kaj and Doornberg, Job N and Jaarsma, Ruurd L and El Moumni, Mostafa and Bleeker, Nils Jan and Plomp, Raul G and IJpma, Frank F A and 3D Surgery Consortium., 3D Surgery Consortium.},
  title = {Development of intraoperative fluoroscopic protocols to avoid rotational malalignment during nailing of femoral fractures: a step-by-step guideline using the lesser trochanter profile or true lateral view},
  journal = {European Journal of Orthopaedic Surgery & Traumatology},
  year = {2026},
  volume = {36},
  number = {1},
  doi = {10.1007/s00590-026-04810-1}
}
Kostenlos starten →