EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieVergleichsstudie

Comparative Efficacy of Hematoma Block Versus Circumferential Block in Pain Management for Distal Radius Fracture Reduction

Natee Kalapukdee, Patarapon Inthawong, Jaruwat Vechasilp, Lertkong Nitiwarangkul, Woraphon Jaroenporn

European Journal of Orthopaedic Surgery & Traumatology · 08.04.2026 · 36 (1)

DOI: 10.1007/s00590-026-04733-x ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, online erschienen am 08.04.2026. Verfasst von Natee Kalapukdee und 4 weiteren Autor:innen. Beteiligte Einrichtung: Ladyao Hospital, 1 moo 8, Nakhon Sawan, 60150, Thailand. Hauptthemen laut MEDLINE: Anesthetics, Local, Closed Fracture Reduction, Nerve Block, Pain Management. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Distal radius fractures are among the most common orthopedic injuries requiring effective pain management during closed reduction. While the hematoma block is widely used, circumferential block has been proposed as an alternative due to its broader analgesic coverage. However, direct comparative evidence remains limited. METHODS: This double-blind randomized controlled trial (RCT) included 51 patients with distal radius fractures treated from June 2023 to May 2024. Patients were randomized into hematoma block or circumferential block groups. Pain levels were measured using the Visual Analog Scale (VAS) at four time points: before injection, 5 min post-injection, during reduction, and 10 min post-reduction. Radiographic alignment and complications were also assessed. RESULTS: Baseline characteristics were comparable between groups (p = 0.42). Pain scores were significantly lower in the circumferential block group across all post-injection time points (p < 0.01). VAS scores: Circumferential block provided better pain relief at 5 min post-injection (1.19 vs. 3.08), during reduction (1.61 vs. 4.96), and 10 min post-reduction (1.50 vs. 4.12). Radiographic alignment outcomes were similar between groups. No adverse events (e.g., neurovascular injury, infection) were reported. CONCLUSIONS: Circumferential block demonstrated superior pain control compared to hematoma block without compromising fracture alignment or increasing complications. Its broader periosteal innervation coverage and ease of administration suggest it may be a valuable alternative for pain management in distal radius fracture reduction. However, further studies with larger sample sizes and long-term functional assessments are warranted to confirm these findings. LEVEL OF EVIDENCE I: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anesthetics, LocalClosed Fracture ReductionNerve BlockPain ManagementPostoperative PainRadius FracturesWrist FracturesAdultAgedFemaleHumansMaleMiddle AgedDouble-Blind MethodHematomaPain MeasurementTreatment Outcome

Stichwörter der Autor:innen

Circumferential blockDistal radius fractureHematoma blockRadiographic alignmentRandomized controlled trialReductionVAS scores

Substanzen

Anesthetics, Local

Autor:innen und Institutionen

  • Ladyao Hospital, 1 moo 8, Nakhon Sawan, 60150, Thailand.
  • Department of Orthopaedics, Police General Hospital, 492/1, Royal Thai Police Headquaters, Bangkok, Thailand.
  • Department of Orthopaedics, Police General Hospital, 492/1, Royal Thai Police Headquaters, Bangkok, Thailand. patarapon.in23@gmail.com.
  • Department of Orthopaedics, Police General Hospital, 492/1, Royal Thai Police Headquaters, Bangkok, Thailand. woraphon.md@gmail.com.

Zitieren

APA

Kalapukdee, N., Inthawong, P., Vechasilp, J., Nitiwarangkul, L., & Jaroenporn, W. (2026). Comparative Efficacy of Hematoma Block Versus Circumferential Block in Pain Management for Distal Radius Fracture Reduction. European Journal of Orthopaedic Surgery & Traumatology, 36(1). https://doi.org/10.1007/s00590-026-04733-x

Vancouver

Kalapukdee N, Inthawong P, Vechasilp J, Nitiwarangkul L, Jaroenporn W. Comparative Efficacy of Hematoma Block Versus Circumferential Block in Pain Management for Distal Radius Fracture Reduction. European Journal of Orthopaedic Surgery & Traumatology. 2026;36(1). doi:10.1007/s00590-026-04733-x

BibTeX
@article{Kalapukdee2026,
  author = {Kalapukdee, Natee and Inthawong, Patarapon and Vechasilp, Jaruwat and Nitiwarangkul, Lertkong and Jaroenporn, Woraphon},
  title = {Comparative Efficacy of Hematoma Block Versus Circumferential Block in Pain Management for Distal Radius Fracture Reduction},
  journal = {European Journal of Orthopaedic Surgery & Traumatology},
  year = {2026},
  volume = {36},
  number = {1},
  doi = {10.1007/s00590-026-04733-x}
}
Kostenlos starten →