EUVIMEDEUVIMED entdecken
Crossref

Sacroiliac fixation in pediatric patients: stability analysis by the finite element method

Heloisa Faggion, Arthur Rossito, Celso Mendonça, Weverley Valenza, Jamil Soni

European Journal of Orthopaedic Surgery & Traumatology · 23.03.2026 · 36 (1)

DOI: 10.1007/s00590-026-04719-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, online erschienen am 23.03.2026. Verfasst von Heloisa Faggion und 4 weiteren Autor:innen. Beteiligte Einrichtung: Hospital do Trabalhador, Curitiba, Brazil. heloisafaggion@gmail.com. Hauptthemen laut MEDLINE: Fracture Fixation, Internal, Sacroiliac Joint, Fractures, Bone, Pelvic Bones. Die Arbeit nennt 19 Literaturangaben. Gefördert von: AO Latin America.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study aimed to evaluate, using the finite element method (FEM), the biomechanical stability of a 3.5 mm cannulated screw for sacroiliac fixation of pelvic fractures in children aged ≤ 5 years. METHODS: A computerized pediatric pelvic model was constructed from a CT scan of a 5-year-old patient. A Torode and Zieg Type IV fracture was simulated and fixed with a 3.5 mm cannulated screw positioned in the oblique S1 corridor. A bipedal support load condition was applied. For FEM analysis, two fixations were tested: one with a 3.5 mm screw (test) and another with a 7.0 mm screw (control). Visual and quantitative assessments of bone fragment displacement, total pelvic displacement, and maximum von Mises stress in the screws were performed. RESULTS: Both constructs showed minimal fracture displacement and equivalent stability. The maximum von Mises stress in the 3.5 mm screw was 738 MPa, exceeding the steel alloy limits for plastic deformation and tensile strength, producing a small region of increased surface stress. CONCLUSION: In a FEM-based model, sacroiliac fixation with a 3.5 mm cannulated screw in the oblique S1 safety corridor provided stable fixation of pediatric pelvic fractures up to 5 years of age. Nevertheless, the stress observed could lead to screw failure. Therefore, strict postoperative load restriction is recommended.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fracture Fixation, InternalSacroiliac JointFractures, BonePelvic BonesHumansFinite Element AnalysisBone ScrewsChild, PreschoolBiomechanical PhenomenaStress, MechanicalTomography, X-Ray Computed

Stichwörter der Autor:innen

Bone screwsChildFinite element analysisFracture fixationSacroiliac joint

Autor:innen und Institutionen

  • Hospital do Trabalhador, Curitiba, Brazil. heloisafaggion@gmail.com.
  • Hospital do Trabalhador, Curitiba, Brazil.
  • Federal University of Paraná, Curitiba, Brazil.

Förderung

  • AO Latin America

Zitieren

APA

Faggion, H., Rossito, A., Mendonça, C., Valenza, W., & Soni, J. (2026). Sacroiliac fixation in pediatric patients: stability analysis by the finite element method. European Journal of Orthopaedic Surgery & Traumatology, 36(1). https://doi.org/10.1007/s00590-026-04719-9

Vancouver

Faggion H, Rossito A, Mendonça C, Valenza W, Soni J. Sacroiliac fixation in pediatric patients: stability analysis by the finite element method. European Journal of Orthopaedic Surgery & Traumatology. 2026;36(1). doi:10.1007/s00590-026-04719-9

BibTeX
@article{Faggion2026,
  author = {Faggion, Heloisa and Rossito, Arthur and Mendonça, Celso and Valenza, Weverley and Soni, Jamil},
  title = {Sacroiliac fixation in pediatric patients: stability analysis by the finite element method},
  journal = {European Journal of Orthopaedic Surgery & Traumatology},
  year = {2026},
  volume = {36},
  number = {1},
  doi = {10.1007/s00590-026-04719-9}
}
Kostenlos starten →