Novel artificial intelligence model predicts the need for reduction of distal radius fractures
European Journal of Orthopaedic Surgery & Traumatology · 2025
DOI: 10.1007/s00590-025-04592-y ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, 2025. Verfasst von Jacob Scioscia und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic Surgery, Baylor College of Medicine, Houston, USA. Hauptthemen laut MEDLINE: Radius Fractures, Artificial Intelligence. Die Arbeit nennt 24 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: Distal radius fractures are among the most common upper extremity injuries. While convolutional neural networks (CNNs) have shown promise in fracture detection, no models have specifically addressed the need for reduction, which is a critical distinction for clinical decision-making. Current AI models detect fractures but fall short in guiding treatment, highlighting an opportunity to enhance triage through AI. METHODS: We retrospectively assembled 495 patients with AP, lateral, and oblique wrist radiographs. To mirror real-world deployment, images were smartphone-style screenshots standardized to 224 × 224 grayscale. We trained BoraeNet, a three-branch DenseNet-169 model (one branch per view) using 5-fold CV on 90% of patients and evaluated a held-out internal test set (n = 50). RESULTS: BoraeNet demonstrated strong performance in classifying fractures needing reduction. Training metrics included accuracy (0.93), precision (0.95), recall (0.91), and F1 score (0.93), with consistent performance across folds. On the held-out internal validation set (n = 50), the model achieved an AUC of 0.89 and average precision of 0.91, classifying 15 true positives, 27 true negatives, 6 false positives, and 2 false negatives. CONCLUSION: The BoraeNet model offers a promising tool using low-fidelity images to predict need for reduction with strong discrimination, supporting triage in resource-limited settings. Future work should include larger datasets with demographic information, object detection, and multi-center external validation and integration into PACS/clinical workflow. Level of Evidence Level III.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedic Surgery, Baylor College of Medicine, Houston, USA.
- Department of Orthopedic Surgery, Baylor College of Medicine, Houston, USA. joshua.morrow@bcm.edu.
Zitieren
APA
Scioscia, J., Fiedler, B., Ghilzai, U., Birhiray, D., Hauck, J., Chilukuri, S., Vemu, R., Morrow, J., & Deveza, L. (2025). Novel artificial intelligence model predicts the need for reduction of distal radius fractures. European Journal of Orthopaedic Surgery & Traumatology. https://doi.org/10.1007/s00590-025-04592-y
Vancouver
Scioscia J, Fiedler B, Ghilzai U, Birhiray D, Hauck J, Chilukuri S, et al. Novel artificial intelligence model predicts the need for reduction of distal radius fractures. European Journal of Orthopaedic Surgery & Traumatology. 2025. doi:10.1007/s00590-025-04592-y
BibTeX
@article{Scioscia2025,
author = {Scioscia, Jacob and Fiedler, Benjamin and Ghilzai, Umar and Birhiray, Dion and Hauck, Jeffrey and Chilukuri, Srikhar and Vemu, Rohan and Morrow, Joshua and Deveza, Lorenzo},
title = {Novel artificial intelligence model predicts the need for reduction of distal radius fractures},
journal = {European Journal of Orthopaedic Surgery & Traumatology},
year = {2025},
doi = {10.1007/s00590-025-04592-y}
}
EUVIMED