The correlation between biomechanical experiments and clinical studies in orthopedics: a systematic review
European Journal of Orthopaedic Surgery & Traumatology · 06.05.2025 · 35 (1)
DOI: 10.1007/s00590-025-04249-w ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, online erschienen am 06.05.2025. Verfasst von Byron A Ward und 1 weiteren Autor:innen. Beteiligte Einrichtung: Denver Health Medical Center, Denver, USA. Hauptthemen laut MEDLINE: Orthopedics, Orthopedic Procedures. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To evaluate the clinical relevance of biomechanical experiments by conducting a systematic review of orthopedic studies that compared treatments with both a biomechanical experiment and a clinical study. METHODS: A systematic search of MEDLINE/PUBMED was performed to identify orthopedic studies that included both a biomechanical experiment and a clinical study to compare treatments. The association between a difference in the outcome of the biomechanical experiment and a difference in the outcome of the clinical study was evaluated. RESULTS: There were 23 studies that were included. The orthopedic specialty of the studies included trauma (n = 17), pediatric trauma (n = 2), sports (n = 2), and hand (n = 1). The anatomic areas of each study included the hip/femur (n = 11), shoulder/humerus (n = 3), elbow/forearm (n = 2), knee/tibia (n = 3), ankle/foot (n = 2), pelvis/acetabulum (n = 1), and hand (n = 1). The biomechanical experiments involved cadavers (n = 14), synthetic bone (n = 5), finite element analysis (n = 3), and animals (n = 1). The biomechanical experiment from each study, compared to the clinical study, was more likely to report a difference in outcomes (82.6% (19/23) vs. 30.4% (7/23), p = 0.0008). The findings of the biomechanical experiment and the clinical study were in agreement in 43.4% (10/23) of the studies. Studies that reported a difference in the biomechanical outcome, compared to those that did not, were not more likely to report a difference in the clinical outcome (31.6% (6/19) vs. 25.0% (1/3), p = 1.0). CONCLUSIONS: The outcomes of biomechanical experiments did not correlate with clinical study outcomes. Considering these findings, the utility of biomechanical experiments in orthopedics should be reexamined. LEVEL OF EVIDENCE: Level 3.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Denver Health Medical Center, Denver, USA.
- Grady Memorial Hospital, Emory University, Atlanta, USA. joshua.a.parry@emory.edu.
Zitieren
APA
Ward, B. A., & Parry, J. A. (2025). The correlation between biomechanical experiments and clinical studies in orthopedics: a systematic review. European Journal of Orthopaedic Surgery & Traumatology, 35(1). https://doi.org/10.1007/s00590-025-04249-w
Vancouver
Ward BA, Parry JA. The correlation between biomechanical experiments and clinical studies in orthopedics: a systematic review. European Journal of Orthopaedic Surgery & Traumatology. 2025;35(1). doi:10.1007/s00590-025-04249-w
BibTeX
@article{Ward2025,
author = {Ward, Byron A and Parry, Joshua A},
title = {The correlation between biomechanical experiments and clinical studies in orthopedics: a systematic review},
journal = {European Journal of Orthopaedic Surgery & Traumatology},
year = {2025},
volume = {35},
number = {1},
doi = {10.1007/s00590-025-04249-w}
}
EUVIMED