Computed tomography-based navigation versus accelerometer-based portable navigation in total hip arthroplasty for dysplastic hip osteoarthritis
European Journal of Orthopaedic Surgery & Traumatology · 2025
DOI: 10.1007/s00590-025-04188-6 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, 2025. Verfasst von Shinya Tanaka und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya-shi, Japan. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Osteoarthritis, Hip, Tomography, X-Ray Computed, Surgery, Computer-Assisted. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Nagoya University.
Abstract (Originalsprache)
Purpose
Accurate cup placement is challenging in total hip arthroplasty (THA) for dysplastic hip osteoarthritis (DHOA) because of the complex morphology of the acetabulum. Studies have reported good accuracy for total hip arthroplasty (THA) using computed tomography-based navigation (CTN); however, in recent years, portable navigation (PN) has become more widely applied because of its low cost and ease of use. This study aimed to compare the accuracy of portable navigation with that of CT-based navigation.
Methods
A total of 114 patients underwent THA for DHOA via the standard posterior approach in the lateral decubitus position using the CTN (CTN-THA group) or PN (PN-THA group) system. After propensity score matching, 32 patients were included in each group. The accuracy of cup inclination, anteversion, cup placement position, and operative time were compared between the groups.
Results
There was no difference in accuracy error between the CTN-THA (inclination 2.8 ± 2.0° and anteversion 3.4 ± 2.1°) and PN-THA groups (inclination 2.5 ± 1.8° and anteversion 2.6 ± 2.2°). The CTN-THA group (inclination 2.2 ± 2.0° and anteversion 2.1 ± 1.6°) achieved better navigation error compared to the PN-THA group (inclination 2.6 ± 2.2° and anteversion 3.8 ± 3.3°). The error of cup placement position in the anteroposterior direction was significantly larger in the PN-THA group (4.27 ± 3.02 mm) than in the CTN-THA group (2.13 ± 2.17 mm). The operative time was significantly longer in the CTN-THA group (115 ± 41 min) than in the PN-THA group (87 ± 19 min).
Conclusions
CTN-THA exhibited better accuracy than PN-THA for both cup placement angles and positions. CTN-THA tended to increase the operative time compared to PN-THA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya-shi, Japan.
- Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya-shi, Japan. ysk0568@yahoo.co.jp.
Förderung
- Nagoya University
Zitieren
APA
Tanaka, S., Osawa, Y., Takegami, Y., Funahashi, H., Ido, H., Asamoto, T., & Imagama, S. (2025). Computed tomography-based navigation versus accelerometer-based portable navigation in total hip arthroplasty for dysplastic hip osteoarthritis. European Journal of Orthopaedic Surgery & Traumatology. https://doi.org/10.1007/s00590-025-04188-6
Vancouver
Tanaka S, Osawa Y, Takegami Y, Funahashi H, Ido H, Asamoto T, et al. Computed tomography-based navigation versus accelerometer-based portable navigation in total hip arthroplasty for dysplastic hip osteoarthritis. European Journal of Orthopaedic Surgery & Traumatology. 2025. doi:10.1007/s00590-025-04188-6
BibTeX
@article{Tanaka2025,
author = {Tanaka, Shinya and Osawa, Yusuke and Takegami, Yasuhiko and Funahashi, Hiroto and Ido, Hiroaki and Asamoto, Takamune and Imagama, Shiro},
title = {Computed tomography-based navigation versus accelerometer-based portable navigation in total hip arthroplasty for dysplastic hip osteoarthritis},
journal = {European Journal of Orthopaedic Surgery & Traumatology},
year = {2025},
doi = {10.1007/s00590-025-04188-6}
}