Diamond-like carbon (DLC) surface treatment decreases biofilm burden by S. aureus on titanium alloy in vitro— a pilot study
European Journal of Orthopaedic Surgery & Traumatology · 2024
DOI: 10.1007/s00590-024-04093-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, 2024. Verfasst von Anabelle Visperas und 7 weiteren Autor:innen. Beteiligte Einrichtung: Cleveland Clinic Adult Reconstruction Research (CCARR), Department of Orthopaedic Surgery, Cleveland Clinic, 9500 Euclid Ave. A40, Cleveland, OH, 441…. Hauptthemen laut MEDLINE: Biofilms, Titanium, Staphylococcus aureus, Alloys. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Signature Orthopaedics.
Abstract (Originalsprache)
Purpose
Periprosthetic joint infection is a complication of total joint arthroplasty with treatment costs over $1.6 billion dollars per year in the US with high failure rates. Therefore, generation of coatings that can prevent infection is paramount. Diamond-like carbon (DLC) is an ideal coating for implants as they are wear-resistant, corrosion-resistant, inert, and have a low friction coefficient. The purpose of this study was to test the efficacy of DLC surface treatment in prevention of biofilm on titanium discs infected with Staphylococcus aureus in vitro.
Methods
Titanium alloy discs ( n = 4 non-coated and n = 4 DLC-coated) were infected with 5 × 10 5 colony-forming units (CFU) of S. aureus for 2 weeks then analysed via crystal violet and scanning electron microscopy (SEM).
Results
Crystal violet analysis yielded differences in the appearance of biofilm on implant surface where DLC-coated had a clumpier appearance but no difference in biofilm quantification. Interestingly, this clumpy appearance did lead to differences in SEM biofilm coverage where significantly less biofilm coverage was found on DLC-coated discs (81.78% vs. 54.17%, p < 0.003).
Conclusion
DLC-coated titanium alloy implants may have preventative properties in S. aureus infection. Observing differences in biofilm coverage does warrant additional testing including CFU titration and biofilm kinetics with eventual use in an animal model of periprosthetic joint infection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Cleveland Clinic Adult Reconstruction Research (CCARR), Department of Orthopaedic Surgery, Cleveland Clinic, 9500 Euclid Ave. A40, Cleveland, OH, 44113, USA.
- Department of Chemistry, Case Western Reserve University, 10900 Euclid Ave., Cleveland, OH, 44106, USA.
- Cleveland Clinic Adult Reconstruction Research (CCARR), Department of Orthopaedic Surgery, Cleveland Clinic, 9500 Euclid Ave. A40, Cleveland, OH, 44113, USA. piuzzin@ccf.org.
Förderung
- Signature Orthopaedics
Zitieren
APA
Visperas, A., Cui, K., Alam, M. M., Subramanian, S., Butsch, E., Klika, A. K., Samia, A. C., & Piuzzi, N. S. (2024). Diamond-like carbon (DLC) surface treatment decreases biofilm burden by S. aureus on titanium alloy in vitro— a pilot study. European Journal of Orthopaedic Surgery & Traumatology. https://doi.org/10.1007/s00590-024-04093-4
Vancouver
Visperas A, Cui K, Alam MM, Subramanian S, Butsch E, Klika AK, et al. Diamond-like carbon (DLC) surface treatment decreases biofilm burden by S. aureus on titanium alloy in vitro— a pilot study. European Journal of Orthopaedic Surgery & Traumatology. 2024. doi:10.1007/s00590-024-04093-4
BibTeX
@article{Visperas2024,
author = {Visperas, Anabelle and Cui, Kaixi and Alam, Md Masud and Subramanian, Shonali and Butsch, Evan and Klika, Alison K and Samia, Anna Cristina and Piuzzi, Nicolas S},
title = {Diamond-like carbon (DLC) surface treatment decreases biofilm burden by S. aureus on titanium alloy in vitro— a pilot study},
journal = {European Journal of Orthopaedic Surgery & Traumatology},
year = {2024},
doi = {10.1007/s00590-024-04093-4}
}
EUVIMED