Short-term primary and revision modular dual-mobility cup total hip arthroplasty outcomes in high-risk dislocation patients: a retrospective study
Kurzfristige Ergebnisse von primärer und revisionsbezogener modularer Dual-Mobility-Cup-Totalendoprothese der Hüfte bei Patient:innen mit hohem Luxationsrisiko: retrospektive Studie
European Journal of Orthopaedic Surgery & Traumatology · 08.09.2024 · 34 (8) · 3981-3988
DOI: 10.1007/s00590-024-04092-5 ↗Auf einen Blick
Bei 101 MDMC-Patient:innen lagen die 2-Jahres-Überlebensraten des Implantats bei primärer THA bei 97 % und bei Revisions-THA bei 90 %. Luxationen traten selten bei primärer THA und häufiger bei Revisions-THA auf.
Fragestellung
Wie sind Implantatüberleben, Komplikationen, Luxationen, Revisionsraten und Mortalität nach MDMC-THA bei Hochrisiko-Patient:innen?
Methode
Retrospektive Kohortenstudie an 101 MDMC-Patient:innen mit mindestens 2 Jahren Nachbeobachtung; Auswertung von Implantatüberleben, Komplikationen und Mortalität.
Ergebnisse
Primäre THA: Implantatüberleben 97 % nach 2 Jahren, Luxation 1,4 %, Mortalität 13 % nach 2 Jahren. Revisions-THA: Implantatüberleben 90 %, Luxation 12,9 %, Mortalität 13 %. Rehospitalisation wegen Luxation sank um 46 %.
Einschränkungen
Retrospektive Einzelzentrumsstudie mit kurzer Nachbeobachtung von mindestens 2 Jahren.
Schlussfolgerung der Autor:innen
Die kurzfristigen Überlebens- und Komplikationsraten nach MDMC waren nach primärer THA ausgezeichnet und nach Revisions-THA moderat. Die Einführung schien die Luxationsrate bei Hüftfrakturpatient:innen zu senken.
Kernaussagen
- 2-Jahres-Implantatüberleben: 97 % primär, 90 % bei Revision
- Luxation: 1,4 % primär, 12,9 % bei Revision
- Rehospitalisation wegen Luxation nach Einführung um 46 % geringer
Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.
Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, online erschienen am 08.09.2024. Verfasst von Martta Ruusiala und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Health Sciences, University of Eastern Finland, Yliopistonranta 1, 70210, Kuopio, Finland. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Reoperation, Hip Prosthesis, Prosthesis Failure. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Eastern Finland.
Themen: Mobilisation
Abstract (Originalsprache)
Purpose
Modular dual-mobility cups (MDMCs) have a lower risk for dislocation after total hip arthroplasty (THA). The primary aims of our study were to analyze implant survivorship and to determine complications, especially dislocation, and revision rates of primary THAs used for hip fracture patients and for revision THAs. Secondary aims were to evaluate mortality after MDMC surgery and to find out if introduction of MDMC at our institution (Kuopio University Hospital, Finland) have decreased dislocation rate.
Methods
This retrospective cohort study consisted of 101 MDMC patients who were consecutively operated at our institution between April 1, 2018 and June 30, 2020. The implant survival rate, complications and mortality were evaluated with minimum of 2-year follow-up. Finnish Hospital Discharge Register was used to find out yearly dislocation rates following THA at our institution.
Results
The cumulative estimate implant survival after MDMC in the primary THA group was 97% at 2 years, and in the revision THA group, it was 90% at 2 years. Dislocation was a rare complication in the primary THA group (1.4%), while it was common in revision THA group (12.9%). The cumulative estimate for mortality after MDMC in the primary THA group was 13% at 2 years, and in the revision group, it was also 13% at 2 years. The yearly number of patients who had re-hospitalization period due to THA dislocation decreased 46% after implementation of MDMC.
Conclusion
Short-term survival and complication rates after MDMC were excellent after primary THA and moderate after revision THA. Implementation of MDMC THA for hip fracture patients seems to have effectively decrease dislocation rate during a short follow-up.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Faculty of Health Sciences, University of Eastern Finland, Yliopistonranta 1, 70210, Kuopio, Finland.
- Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, P.O. Box 1777, 70211, Kuopio, Finland.
- Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, P.O. Box 1777, 70211, Kuopio, Finland. simo.miettinen@kuh.fi.
- Faculty of Health Sciences, University of Eastern Finland, Yliopistonranta 1, 70210, Kuopio, Finland. simo.miettinen@kuh.fi.
Förderung
- University of Eastern Finland
Zitieren
APA
Ruusiala, M., Miettinen, H., Kettunen, J., Kröger, H., & Miettinen, S. (2024). Short-term primary and revision modular dual-mobility cup total hip arthroplasty outcomes in high-risk dislocation patients: a retrospective study. European Journal of Orthopaedic Surgery & Traumatology, 34(8), 3981-3988. https://doi.org/10.1007/s00590-024-04092-5
Vancouver
Ruusiala M, Miettinen H, Kettunen J, Kröger H, Miettinen S. Short-term primary and revision modular dual-mobility cup total hip arthroplasty outcomes in high-risk dislocation patients: a retrospective study. European Journal of Orthopaedic Surgery & Traumatology. 2024;34(8):3981-3988. doi:10.1007/s00590-024-04092-5
BibTeX
@article{Ruusiala2024,
author = {Ruusiala, Martta and Miettinen, Hannu and Kettunen, Jukka and Kröger, Heikki and Miettinen, Simo},
title = {Short-term primary and revision modular dual-mobility cup total hip arthroplasty outcomes in high-risk dislocation patients: a retrospective study},
journal = {European Journal of Orthopaedic Surgery & Traumatology},
year = {2024},
volume = {34},
number = {8},
pages = {3981--3988},
doi = {10.1007/s00590-024-04092-5}
}
EUVIMED