Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, 2024. Verfasst von Yash P Chaudhry und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Philadelphia College of Osteopathic Medicine, 4190 City Avenue, Philadelphia, PA, 19131, USA. yash.chaudhry.21@gma…. Hauptthemen laut MEDLINE: Fracture Fixation, Intramedullary, Tibial Fractures, Fibula, Bone Malalignment. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Malalignment of distal tibia fractures can lead to malunion/nonunion or alter the limb mechanical axis which may cause arthritis. Proposed methods to decrease malalignment include fibular fixation or multiplanar interlocking screws, however these remain controversial. This study aimed to identify factors associated with malalignment in distal tibial fractures with associated fibular shaft fractures.
Methods
A retrospective review was performed of distal tibia fractures with associated fibular shaft fractures treated with intramedullary nailing at two level one trauma centers between 2015 and 2019. Cases involving malalignment (> 5° of deviation from anatomic axis on either coronal/sagittal axis) on final follow-up (minimum three months postoperatively) were compared to those without malalignment with regard to demographics, fracture characteristics, intraoperative characteristics, and complications.
Results
The rate of malalignment was 13%. On multivariate analysis, multiplanar distal interlocking screw fixation (odds ratio [OR], 0.18; 95% confidence interval [CI] 0.03–0.92) was associated with a decreased rate of final malalignment, while nail diameter > 10 mm was associated with a higher rate (OR, 4.05; 95% CI 1.25–13.11). Fibular fixation was not associated with malalignment.
Conclusion
Multiplanar distal interlocking screws may protect against malalignment. Fibula fixation does not appear associated with a decreased rate of malalignment in distal tibia fractures treated with intramedullary nails. Level of Evidence III.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Philadelphia College of Osteopathic Medicine, 4190 City Avenue, Philadelphia, PA, 19131, USA. yash.chaudhry.21@gmail.com.
- Department of Orthopaedics, UT Health San Antonio, San Antonio, TX, USA.
- Department of Orthopaedic Surgery, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.
- Faculty of Medicine Vajira Hospital, Navamindradhiraj University, Bangkok, Thailand.
- Holy Spirit Medical Center Penn State Health, Orthopaedic Institute of Pennsylvania, Camp Hill, PA, USA.
Zitieren
APA
Chaudhry, Y. P., Gutierrez-Naranjo, J. M., Raad, M., Ghanem, D., Salazar, L. M., Goodrum, J. T., Luksameearunothai, K., Zelle, B. A., & Hasenboehler, E. A. (2024). Risk factors for malalignment after intramedullary nail treatment of distal tibia fractures with associated fibula fractures. European Journal of Orthopaedic Surgery & Traumatology. https://doi.org/10.1007/s00590-024-04062-x
Vancouver
Chaudhry YP, Gutierrez-Naranjo JM, Raad M, Ghanem D, Salazar LM, Goodrum JT, et al. Risk factors for malalignment after intramedullary nail treatment of distal tibia fractures with associated fibula fractures. European Journal of Orthopaedic Surgery & Traumatology. 2024. doi:10.1007/s00590-024-04062-x
BibTeX
@article{Chaudhry2024,
author = {Chaudhry, Yash P and Gutierrez-Naranjo, Jose M and Raad, Micheal and Ghanem, Diane and Salazar, Luis M and Goodrum, Jason T and Luksameearunothai, Kitchai and Zelle, Boris A and Hasenboehler, Erik A},
title = {Risk factors for malalignment after intramedullary nail treatment of distal tibia fractures with associated fibula fractures},
journal = {European Journal of Orthopaedic Surgery & Traumatology},
year = {2024},
doi = {10.1007/s00590-024-04062-x}
}
EUVIMED