Rates of interlock screw back-out are high with the retrograde femoral nailing advanced system for distal femur fractures
European Journal of Orthopaedic Surgery & Traumatology · 2024
DOI: 10.1007/s00590-024-04006-5 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, 2024. Verfasst von Rahul Bhale und 5 weiteren Autor:innen. Beteiligte Einrichtung: Davis Department of Orthopaedic Surgery, University of California, 4860 Y St #1700, Sacramento, CA, 95817, USA. Hauptthemen laut MEDLINE: Femoral Fractures, Fracture Fixation, Intramedullary, Bone Nails, Bone Screws. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
The retrograde femoral nailing advanced (RFNA) system (DePuy synthes) is a commonly used implant for the fixation of low distal femur and periprosthetic fractures. There is concern that the rate of distal interlock screw back-out may be higher for the RFNA compared to other nails (ON). The purpose of this study was to evaluate the incidence of interlock screw back-out and associated screw removal for RFNA versus ON, along with associated risk factors.
Methods
A retrospective comparative study of patients who underwent retrograde nailing for a distal femur fracture at an academic level one trauma center was performed. The incidence of distal interlock screw back-out and need for screw removal were compared for RFNA versus a propensity score matched cohort who received other nails.
Results
One hundred and ten patients underwent retrograde nailing with the RFNA for a distal femur fracture from 2015 to 2022 (average age: 66, BMI: 32, 52.7% smokers, 54.5% female, 61.8%). There was a significantly higher rate of interlock back-out in the RFNA group compared to the ON (27 patients, 24.5% vs 12 patients, 10.9%, p = 0.01), which occurred 6.3 weeks postoperatively. Screw removal rates for back-out were not significantly different for the RFNA group versus ON (8 patients, 7.3% vs 3 patients, 2.7%, p = 0.12).
Conclusion
In this retrospective comparative study of distal femur fractures treated with retrograde nailing, the RFNA implant was associated with an increased risk of distal interlock screw back-out compared to other nails.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Davis Department of Orthopaedic Surgery, University of California, 4860 Y St #1700, Sacramento, CA, 95817, USA.
- Davis Department of Orthopaedic Surgery, University of California, 4860 Y St #1700, Sacramento, CA, 95817, USA. amsaiz@ucdavis.edu.
Zitieren
APA
Bhale, R., Campbell, S. T., Fitzpatrick, E., Soles, G., Lee, M., & Saiz, A. M. (2024). Rates of interlock screw back-out are high with the retrograde femoral nailing advanced system for distal femur fractures. European Journal of Orthopaedic Surgery & Traumatology. https://doi.org/10.1007/s00590-024-04006-5
Vancouver
Bhale R, Campbell ST, Fitzpatrick E, Soles G, Lee M, Saiz AM. Rates of interlock screw back-out are high with the retrograde femoral nailing advanced system for distal femur fractures. European Journal of Orthopaedic Surgery & Traumatology. 2024. doi:10.1007/s00590-024-04006-5
BibTeX
@article{Bhale2024,
author = {Bhale, Rahul and Campbell, Sean T and Fitzpatrick, Ellen and Soles, Gillian and Lee, Mark and Saiz, Augustine M},
title = {Rates of interlock screw back-out are high with the retrograde femoral nailing advanced system for distal femur fractures},
journal = {European Journal of Orthopaedic Surgery & Traumatology},
year = {2024},
doi = {10.1007/s00590-024-04006-5}
}
EUVIMED