Do the humeral radiographic changes at 5-year follow-up affect the clinical outcomes of press-fit humeral stems in primary reverse shoulder arthroplasties?
European Journal of Orthopaedic Surgery & Traumatology · 03.03.2024 · 34 (4) · 1851-1863
DOI: 10.1007/s00590-024-03864-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, online erschienen am 03.03.2024. Verfasst von Carlos García-Fernández und 7 weiteren Autor:innen. Beteiligte Einrichtung: Shoulder and Elbow Unit, Department of Orthopaedic Surgery and Traumatology, Hospital Clínico San Carlos, C/Profesor Martín Lagos S/N, 28040, Madrid,…. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Range of Motion, Articular, Radiography, Humerus. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 35 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: The purposes of this study were to analyze and compare the functional outcomes and radiological changes around the press-fit humeral components in two contemporary medialized reverse total shoulder arthroplasty (RTSA) systems at a minimum of 5-year follow-up. MATERIALS AND METHODS: Between December 2003 and December 2015, 249 consecutive RTSAs were performed at our hospital. Of these, 68 primary uncemented RTSA met our inclusion criteria. The Constant-Murley score (CMS), the modified Constant score, a visual analog scale (VAS) and active shoulder range of motion (ROM) were measured pre- and postoperatively. Radiological assessment was performed by plain radiographs at a minimum of 5 years postoperatively. RESULTS: At a mean follow-up of 80.2 months, there was no significant difference (p = .59) between the postoperative functional scores and range of motion of the two groups (Delta Xtend and Lima SMR). Radiological data of stress-shielding were observed in 38 patients (55.9%) being slightly more frequent in the Lima SMR group (21 patients) than in the Delta Xtend group (17 patients) (p = .62). CONCLUSIONS: Our study shows that the good functional results are similar between the two uncemented RTSA systems used and that they do not depend on the presence of radiological changes (stress-shielding) in the humeral stem at a minimum 5-year follow-up.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Shoulder and Elbow Unit, Department of Orthopaedic Surgery and Traumatology, Hospital Clínico San Carlos, C/Profesor Martín Lagos S/N, 28040, Madrid, Spain. carlosgf1969@gmail.com.
- Shoulder and Elbow Unit, Department of Orthopaedic Surgery and Traumatology, Hospital Clínico San Carlos, C/Profesor Martín Lagos S/N, 28040, Madrid, Spain.
- Department of Surgery, Facultad de Medicina, Universidad Complutense, Madrid, Spain.
Zitieren
APA
García-Fernández, C., Lopiz, Y., Garríguez-Pérez, D., Arvinius, C., Ponz, V., Echevarria, M., Garrido, A., & Marco, F. (2024). Do the humeral radiographic changes at 5-year follow-up affect the clinical outcomes of press-fit humeral stems in primary reverse shoulder arthroplasties?. European Journal of Orthopaedic Surgery & Traumatology, 34(4), 1851-1863. https://doi.org/10.1007/s00590-024-03864-3
Vancouver
García-Fernández C, Lopiz Y, Garríguez-Pérez D, Arvinius C, Ponz V, Echevarria M, et al. Do the humeral radiographic changes at 5-year follow-up affect the clinical outcomes of press-fit humeral stems in primary reverse shoulder arthroplasties?. European Journal of Orthopaedic Surgery & Traumatology. 2024;34(4):1851-1863. doi:10.1007/s00590-024-03864-3
BibTeX
@article{GarcaFernndez2024,
author = {García-Fernández, Carlos and Lopiz, Yaiza and Garríguez-Pérez, Daniel and Arvinius, Camilla and Ponz, Virginia and Echevarria, Marta and Garrido, Ana and Marco, Fernando},
title = {Do the humeral radiographic changes at 5-year follow-up affect the clinical outcomes of press-fit humeral stems in primary reverse shoulder arthroplasties?},
journal = {European Journal of Orthopaedic Surgery & Traumatology},
year = {2024},
volume = {34},
number = {4},
pages = {1851--1863},
doi = {10.1007/s00590-024-03864-3}
}
EUVIMED