EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cancellous compression bone grafting using headless screw as a strut in scaphoid nonunion by a single volar approach

Anil K Bhat, Sourab Shetty, Ashwath M Acharya

European Journal of Orthopaedic Surgery & Traumatology · 2023

DOI: 10.1007/s00590-023-03485-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, 2023. Verfasst von Anil K Bhat und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Kasturba Medical College-Manipal, Manipal Academy of Higher Education (MAHE), Manipal, Udupi, Karnataka, 576104, India. Hauptthemen laut MEDLINE: Fractures, Ununited, Scaphoid Bone. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Manipal Academy of Higher Education, Manipal.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

An array of fixation and grafting techniques for scaphoid nonunion have been described over time, achieving varied results pertaining to union and scaphoid alignment. The aim of this study was to check for union rates and correction of scaphoid parameters achieved by our technique of using screw as a strut and cancellous compression grafting harvested from the distal radius by a single volar approach.

Methods

Retrospective analysis of all patients operated by the said technique was done from 2013 to 2019. Thirty-eight patients including 36 males and two females in the age range of 20–56 years were analyzed. Union rates, change in scaphoid alignment parameters and graft site characteristics were documented.

Results

Of the patients analyzed, 5/38 were nonunions of proximal pole, 19/38 of waist and 14/38 were of distal pole which included nonunions of cystic type or with humpback deformity. Patients were followed up for an average of 22.2 months and union was achieved in all cases with a mean period of 15.7 ± 3.7 weeks. There was significant improvement in the scaphoid alignment postoperatively. One case of implant migration and one case of scaphoid nonunion advanced collapse were noted. The mean duration of donor site healing was noted to be 16.9 ± 2.5 weeks except two outliers which took longer time. There were no cases of donor site fracture or other complications.

Conclusion

Union rates, correction of scaphoid parameters and minimal complications justifies this technique as a novel one in the management of scaphoid nonunion at all levels, with minimal donor site morbidity and attained by the single volar approach.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fractures, UnunitedScaphoid BoneMaleFemaleHumansYoung AdultAdultMiddle AgedBone TransplantationRetrospective StudiesFracture Fixation, InternalBone ScrewsFracture Healing

Stichwörter der Autor:innen

Compression graftingPure cancellous graftingScaphoid nonunionScaphoid screw fixationScaphoid volar approach

Autor:innen und Institutionen

  • Department of Orthopaedics, Kasturba Medical College-Manipal, Manipal Academy of Higher Education (MAHE), Manipal, Udupi, Karnataka, 576104, India.
  • Department of Orthopaedics, Kasturba Medical College-Manipal, Manipal Academy of Higher Education (MAHE), Manipal, Udupi, Karnataka, 576104, India. sourab.shetty@manipal.edu.

Förderung

  • Manipal Academy of Higher Education, Manipal

Zitieren

APA

Bhat, A. K., Shetty, S., & Acharya, A. M. (2023). Cancellous compression bone grafting using headless screw as a strut in scaphoid nonunion by a single volar approach. European Journal of Orthopaedic Surgery & Traumatology. https://doi.org/10.1007/s00590-023-03485-2

Vancouver

Bhat AK, Shetty S, Acharya AM. Cancellous compression bone grafting using headless screw as a strut in scaphoid nonunion by a single volar approach. European Journal of Orthopaedic Surgery & Traumatology. 2023. doi:10.1007/s00590-023-03485-2

BibTeX
@article{Bhat2023,
  author = {Bhat, Anil K and Shetty, Sourab and Acharya, Ashwath M},
  title = {Cancellous compression bone grafting using headless screw as a strut in scaphoid nonunion by a single volar approach},
  journal = {European Journal of Orthopaedic Surgery & Traumatology},
  year = {2023},
  doi = {10.1007/s00590-023-03485-2}
}
Kostenlos starten →