Purpose
To develop a model that predicts screw loosening at user-specified postoperative time points after lumbar fusion.
Methods
We retrospectively enrolled patients who underwent single-level lumbar interbody fusion at five hospitals: three hospitals for training and two for external testing. Preoperative CT images, clinical characteristics, and postoperative follow-up CT images were collected. Many patients had multiple follow-up CT scans, with screw loosening evaluated for each. Multimodal models were developed using preoperative CT images and the day of the follow-up CT scans as inputs and the occurrence of screw loosening on that day as the label. Three types of preoperative CT images were prepared and used for training: original, whole vertebra, and vertebral body. The results were evaluated in testing, and the best model with the highest AUC among the three was selected. Additionally, clinical characteristics were incorporated as an additional input, and the result was also evaluated.
Results
A total of 212 patients (mean age, 66.5 ± 11.3, 123 male) with 552 follow-up CT scans were included: 412 follow-ups for training and validation, and 140 follow-ups for testing. The model using vertebral body showed the best performance, with an AUC of 0.823 (95% CI, 0.737–0.895) and a sensitivity of 0.914 (95% CI, 0.769–0.999). When clinical characteristics were added to the input, no improvement was observed, with an AUC of 0.721 (95% CI, 0.621–0.817).
Conclusion
The model predicted screw loosening at any postoperative time point with high AUC and sensitivity and has the potential to enable more thorough patient management.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Charité Universitätsmedizin Berlin, Berlin, Germany. satoru.tanioka.ns@icloud.com.
- Mie University Graduate School of Medicine, Tsu, Japan. satoru.tanioka.ns@icloud.com.
- Charité Universitätsmedizin Berlin, Berlin, Germany.
- Mie University Graduate School of Medicine, Tsu, Japan.
- Kuwana City Medical Center, Kuwana, Japan.
- Mie Chuo Medical Center, Hisai, Japan.
ORCID-Profile: Satoru Tanioka
Zitieren
APA
Tanioka, S., Aydin, O. U., Hilbert, A., Miyazaki, T., Yamamoto, A., Ikezawa, M., Nishikawa, H., Fujimoto, M., Ishida, F., Kamei, Y., Yoshida, K., Shoda, M., Suzuki, H., Mizuno, M., & Frey, D. (2026). Multimodal model predicts screw loosening at user-specified postoperative time points after single-level lumbar interbody fusion. European Spine Journal. https://doi.org/10.1007/s00586-026-10268-w
Vancouver
Tanioka S, Aydin OU, Hilbert A, Miyazaki T, Yamamoto A, Ikezawa M, et al. Multimodal model predicts screw loosening at user-specified postoperative time points after single-level lumbar interbody fusion. European Spine Journal. 2026. doi:10.1007/s00586-026-10268-w
BibTeX
@article{Tanioka2026,
author = {Tanioka, Satoru and Aydin, Orhun Utku and Hilbert, Adam and Miyazaki, Takahiro and Yamamoto, Atsushi and Ikezawa, Munenari and Nishikawa, Hirofumi and Fujimoto, Masashi and Ishida, Fujimaro and Kamei, Yusuke and Yoshida, Koichiro and Shoda, Motoi and Suzuki, Hidenori and Mizuno, Masaki and Frey, Dietmar},
title = {Multimodal model predicts screw loosening at user-specified postoperative time points after single-level lumbar interbody fusion},
journal = {European Spine Journal},
year = {2026},
doi = {10.1007/s00586-026-10268-w}
}
EUVIMED